Related Experiment Video
Updated: Feb 9, 2026

Design and Implementation of an fMRI Study Examining Thought Suppression in Young Women with, and At-risk, for Depression
Published on: May 19, 2015
Accuracy and Acceptability of a Screening Tool for Identifying Intimate Partner Violence Perpetration among Women
Galina A Portnoy1, Sally G Haskell1, Matthew W King2
1VA Connecticut Healthcare System, West Haven, Connecticut; Yale School of Medicine, New Haven, Connecticut.
Objectives:
Veterans are at heightened risk for perpetrating intimate partner violence (IPV), yet there is limited evidence to inform practice and policy for the detection of IPV perpetration. The present study evaluated the accuracy and acceptability of a potential IPV perpetration screening tool for use with women veterans.
Design:
A national sample of women veterans completed a 2016 web-based survey that included a modified 5-item Extended-Hurt/Insult/Threaten/Scream (Modified E-HITS) and the Revised Conflict Tactics Scales (CTS-2). Items also assessed women's perceptions of the acceptability and appropriateness of the modified E-HITS questions for use in healthcare settings. Accuracy statistics, including sensitivity and specificity, were calculated using the CTS-2 as the reference standard.
Main Outcome Measures:
Primary measures included the Modified E-HITS (index test), CTS-2 (reference standard), and items assessing acceptability.
Results:
This study included 187 women, of whom 31 women veterans (16.6%) reported past-6-month IPV perpetration on the CTS-2. The Modified E-HITS demonstrated good overall accuracy (area under the curve, 0.86; 95% confidence interval, 0.78-0.94). In addition, the majority of women perceived the questions to be acceptable and appropriate.
Conclusions:
Findings demonstrate that the Modified E-HITS is promising as a low-burden tool for detecting of IPV perpetration among women veterans. This tool may help the Veterans Health Administration and other health care providers detect IPV perpetration and offer appropriate referrals for comprehensive assessment and services.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Improving Translational Accuracy
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Aggression
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.

