Midterm failure of combined phacoemulsification with trabecular microbypass stenting: Clinicopathological analysis
Manjool Shah1, Xavier Campos-Möller1, Liliana Werner1
1From the Department of Ophthalmology and Visual Sciences (Shah), W.K. Kellogg Eye Center, University of Michigan, Ann Arbor, Michigan, and the Department of Ophthalmology and Visual Sciences (Werner, Mamalis), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA; Western Health Eye Care Center (Campos-Möller), Corner Brook, Newfoundland, the Department of Ophthalmology and Vision Sciences (Ahmed), University of Toronto, Toronto, Prism Eye Institute (Ahmed), Mississauga, and Trillium Health Partners (Ahmed), Mississauga, Ontario, Canada.
Abstract:
A propagation of microinvasive glaucoma surgery (MIGS) techniques and devices has resulted in the availability of multiple new modalities for surgical intervention for open-angle glaucoma. As MIGS devices and methods approach a new phase in maturity, midterm failures will inevitably be reported. Although MIGS techniques prioritize safety, an understanding of the potential mechanisms of failure is paramount. In this case of a midterm failure of a trabecular microbypass, clinical findings and pathological correlates allow for a comprehensive understanding of the means by which MIGS devices might fail and offer the opportunity for intervention and potential prevention.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
09:36Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
Published on: March 14, 2018
Related Concept Videos
Pathophysiology of Heart Failure
Heart Failure I: Introduction
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Heart Failure II: Pathophysiology