Related Experiment Video
Updated: Feb 9, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Hemodynamic Assessment of Patients With and Without Heart Failure Symptoms Supported by a Continuous-Flow Left
Rabea Asleh1, Tal Hasin2, Alexandros Briasoulis3
1Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN.
Objective:
To investigate differences in invasive hemodynamic parameters and outcomes in patients with and without heart failure (HF) symptoms after left ventricular assist device (LVAD) implantation.
Patients And Methods:
We performed a single-center retrospective analysis of 51 symptomatic patients and 50 patients with resolved HF symptoms who underwent right-sided heart catheterization (RHC) after LVAD implantation from March 1, 2007, through June 30, 2016. Patient characteristics and outcomes including all-cause mortality and right ventricular (RV) failure were compared between groups.
Results:
Fifty-one patients had development of HF symptoms after LVAD implantation and underwent RHC a mean ± SD of 243.7±288 days postoperatively. Fifty asymptomatic LVAD recipients underwent routine RHC 278.6±205 days after implantation. Compared with patients who had resolved HF symptoms, symptomatic patients were older, more likely to be male, and more likely to have ischemic cardiomyopathy. Symptomatic patients had higher right atrial pressure (P<.001), mean pulmonary arterial pressure (P<.001), and pulmonary capillary wedge pressure (P<.001). Improvements in right atrial pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure before and after LVAD implantation were less remarkable in symptomatic patients. The frequency of RV dysfunction was significantly higher among symptomatic patients than patients with resolved HF symptoms (P=.001). Symptomatic patients displayed significantly higher risk of all-cause mortality (hazard ratio, 3.0; 95% CI, 1.3-6.5; P=.007) and RV failure (hazard ratio, 6.2; 95% CI, 1.3-29.7; P=.02) independent of other predictors of outcome.
Conclusion:
Patients with recurrent HF symptoms after LVAD implantation display more profound hemodynamic derangements, greater burden of RV failure, and increased rates of all-cause mortality compared with LVAD recipients with resolved HF symptoms.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Heart Failure II: Pathophysiology
Pathophysiology of Heart Failure
Heart Failure I: Introduction
Heart Failure VI: Adjunct Therapies
Heart Failure Drugs: Diuretics
Heart Failure V: Medical Management