Related Experiment Video
Updated: Feb 9, 2026

Modeling Biological Membranes with Circuit Boards and Measuring Electrical Signals in Axons: Student Laboratory Exercises
Published on: January 18, 2011
The stripping effect of using high voltage electrical pulses breakage for waste printed circuit boards
Chenlong Duan1, Jun Han1, Shen Zhao1
1Key Laboratory of Coal Processing and Efficient Utilization of Ministry of Education, School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China.
Abstract:
In this study, high voltage electrical pulses were utilized to process waste printed circuit boards to cost effectively liberate metal and nonmetal materials. Relative mass ωiand particles content ηiindexes were defined to assess the stripping effect produced by high voltage electrical pulses breakage. For relative mass level in the 0-10% range, in the -6+3 mm fraction, particles content accounted for 84.84% of the total particles, while the mechanical crushing only occupied 8.84%. Voltage and pulse experiments were carried out to investigate the crushing effect of high voltage electrical pulse breakage for printed circuit boards. It was found that when the voltage and pulse number was at 160 kV and 300, the stripping rate of copper was 98.56% and 92.58% in the -25+13 mm fraction respectively. The measured bending strength of the material revealed the selective crushing effect of high voltage electrical pulses in the different material interfaces. A liberation mechanism was elaborated by using the energy band theory, and a process model was utilized to reveal the mode of crushing. Furthermore, the microscopic appearance of the resulting product confirmed that copper underwent high-temperature melting, while the resin was decomposed during the crushing process. Compared to conventional mechanical crushing process, high voltage electrical pulses can better liberate metal-bearing than mechanical comminution technology.
Related Concept Videos
Voltage Doubler Circuit
Electric Circuit Elements
The most...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Voltage

