Controlling Pd(IV) reductive elimination pathways enables Pd(II)-catalysed enantioselective C(sp3)-H fluorination

Hojoon Park1, Pritha Verma1, Kai Hong1

  • 1Department of Chemistry, The Scripps Research Institute, La Jolla, California, USA.

Nature Chemistry
|June 13, 2018
PubMed

Related Concept Videos

PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
659
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
408
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
392
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection00:59

Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection

In pharmacokinetics, the elimination rate of a drug following a capacity-limited model is primarily controlled by two parameters: Vmax and KM. These parameters are crucial in how the drug behaves inside the body after administration.
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
428
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

Oxidation–Reduction Reactions
75.8K
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution01:09

One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution

The one-compartment open model is a simplified approach used in pharmacokinetics to understand the distribution and elimination of a drug administered through an intravenous bolus. This model assumes rapid drug dispersal throughout the body and elimination using a first-order process. Key pharmacokinetic parameters, such as the elimination rate constant (k), half-life (t1/2), and the apparent volume of distribution (Vd), can be estimated from this model. The elimination rate is calculated...
897