An ELISA Based Binding and Competition Method to Rapidly Determine Ligand-receptor Interactions
Published on: March 14, 2016
[Clinical application of homemade ELISA kit for anti-human phospholipase A2 receptor antibody]
Limin Huang1, Dazhun Zhang2, Yan Wang1
1Department of Nephrology, Peking University Shenzhen Hospital, Shenzhen 518035, Guangdong, China.
To develop and evaluate an ELISA kit for Anti-PLA2R IgG. Recombinant M-type phospholipase A2 receptor (PLA2R) protein expressed in HEK293 was taken as coating antigen, HRP-labeled rabbit anti-human IgG was taken as a tracer, to test the anti-PLA2R IgG on the basis of the principle of ELISA. The detection linear range, accuracy, linear correlation, repeatability, and stability were evaluated. In addition, we made a comparison with enrolled anti-PLA2R IgG kit. The detection linear range of the kit is no more than 2 RU/mL. The relative deviation of the kit accuracy is in -15%-15%. There is a linear correlation coefficient of higher than 0.990 0 within 2-500 RU/mL range. The CV of the repeatable test is lower than 15% when the kit was put in 37 ℃ one week, 2-8 ℃ one year, the performance remains. The consistency of testing with comparison in enrolled anti-PLA2R IgG kit is 98.9% (positive: 97.2%, negative: 100%). The Anti-PLA2R IgG ELISA Kit which we developed is nearly identical to the reference standard in specific and sensitive of clinics. It's successfully used to determine anti-PLA2R titer and help clinical diagnosis.
To develop and evaluate an ELISA kit for Anti-PLA2R IgG. Recombinant M-type phospholipase A2 receptor (PLA2R) protein expressed in HEK293 was taken as coating antigen, HRP-labeled rabbit anti-human IgG was taken as a tracer, to test the anti-PLA2R IgG on the basis of the principle of ELISA. The detection linear range, accuracy, linear correlation, repeatability, and stability were evaluated. In addition, we made a comparison with enrolled anti-PLA2R IgG kit. The detection linear range of the kit is no more than 2 RU/mL. The relative deviation of the kit accuracy is in -15%-15%. There is a linear correlation coefficient of higher than 0.990 0 within 2-500 RU/mL range. The CV of the repeatable test is lower than 15% when the kit was put in 37 ℃ one week, 2-8 ℃ one year, the performance remains. The consistency of testing with comparison in enrolled anti-PLA2R IgG kit is 98.9% (positive: 97.2%, negative: 100%). The Anti-PLA2R IgG ELISA Kit which we developed is nearly identical to the reference standard in specific and sensitive of clinics. It's successfully used to determine anti-PLA2R titer and help clinical diagnosis.
Related Concept Videos
Clinical Applications of Epidermal Stem Cells
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Internal Receptors
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...