Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter
S V Setlur Nagesh1, R Rana1, D R Bednarek1
1Canon (Toshiba) Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14214.
Abstract:
Using anti-scatter grids with high-resolution imaging detectors could result in grid-line artifacts, with increasing severity as detector resolution improves. Grid-line mask subtraction can result in residual artifacts that are due to residual scatter penetrating the grid and not subtracted. By subtracting this residual scatter, the grid artifacts can be minimized. In the previous works, an initial residual-scatter estimate was derived by placing lead markers on a test object; however, any change in the object geometry requires a new scatter estimate. Such a method is impractical to implement during a clinical procedure. In this work, we present a new method to derive the initial scatter estimate to eliminate grid-line artifacts during a procedure. A standard stationary Smit-Roentgen x-ray grid (line density - 70 lines/cm, grid ratio - 13:1) was used with a high-resolution CMOS detector (Dexela Model 1207, pixel size - 75 μm) to image an anthropomorphic head phantom. The initial scatter estimate was derived from the image itself and the grid artifacts were eliminated using recursive correction estimation; this result was compared to that with the estimate derived from placing lead markers on the phantom. In both cases, the contrast-to-noise ratio (CNR) was improved compared to the original image with grid artifacts. Percentage differences in CNR's for three regions between the images corrected with the two estimates were less than 5%. With the new method no a priori scatter distribution profiles are needed, eliminating the need to have libraries of pre-calculated scatter profiles and making the implementation more clinically practical.
More Related Videos
Related Concept Videos
Scatter Plot
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Drug Distribution as One-Compartment Model and Elimination by Nonlinear Pharmacokinetics: Overview
For instance, consider the metabolism of sodium salicylate. This compound is metabolized into two distinct substances: a glucuronide and a glycine conjugate. The rate of conjugation depends...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...