[Determination of chlorfenapyr and indoxacarb in tea by gas chromatography-mass spectrometry with solid phase extraction]
Related Experiment Video
Updated: Feb 9, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Hua Zhou1, Yun Zhang1, Pinggu Wu1
1College of Public Health, Zhejiang University, Hangzhou 310058, China.
Objective:
To establish a method for simultaneous determination of chlorfenapyr and indoxacarb in tea by gas chromatography-mass spectrometry.
Methods:
The tea samples were homogenized and extracted with acetonitrile. Extracts obtained through centrifugation were cleaned up by CARB / NH2 cartridges, and further purified with SLH cartridges. After separated by DB-5MS capillary column( 30 m × 0. 25 mm × 0. 25μm), the analytes were measured by gas chromatography-mass spectrometry in selective ion monitoring( SIM) mode and quantified by external standard method.
Results:
The linear range was 0. 10- 10 μg / m L for both of the two pesticides. The detection limits of chlorfenapyr and indoxacarb in tea samples were 0. 01 and 0. 008 mg / kg, and the quantitation limits were 0. 03 and 0. 025 mg / kg, respectively. The recoveries were from75. 6% to 92. 7%, and the relative standarddeviations( RSDs) were 3. 6%- 11. 4%( n =6).
Conclusion:
The proposed method has good purification effect and high accuracy, which is capable for simultaneously detecting the chlorfenapyr and indoxacarb in tea samples.
More Related Videos
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II