Maximum Strength, Rate of Force Development, Jump Height, and Peak Power Alterations in Weightlifters across Five

W Guy Hornsby1, Jeremy A Gentles2, Christopher J MacDonald3

  • 1Department of Coaching and Teaching Studies, West Virginia University, 375 Birch Street, Morgantown, WV 26505, USA. william.hornsby@mail.wvu.edu.

Related Concept Videos

Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
934
The Maximum Power Transfer Theorem01:20

The Maximum Power Transfer Theorem

Consider a linear AC Thevenin equivalent circuit connected to a load impedance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
1.2K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
621
Determination of Michaelis Constant and Maximum Elimination Rate01:20

Determination of Michaelis Constant and Maximum Elimination Rate

The Michaelis constant (KM) and the theoretical maximum process rate (Vmax) are vital parameters in the Michaelis-Menten equation, central to many biochemical reactions. They provide essential insights into enzyme kinetics and drug metabolism.
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
485
Power Expended by a Constant Force00:57

Power Expended by a Constant Force

The relationship between work done and the time taken to do it can be explained using the concept of power. For example, several sprinters in a race may have the same velocity when they reach the finish line, therefore doing the same amount of work, but the winner does it in the least amount of time. Thus, power is defined as the rate of doing work. Since work can vary as a function of time, the average power is defined as the work done during a time interval, divided by the time interval.
9.2K
Hydraulic Jump: Problem Solving01:16

Hydraulic Jump: Problem Solving

To analyze a hydraulic jump in a rectangular channel with a flow speed of 6 meters per second, follow these steps:Calculate Effective Upstream Velocity:When the downstream gate closes, a hydraulic jump forms, traveling upstream at 2 meters per second. This wave speed combines with the initial channel flow velocity, creating an effective upstream velocity.Identify Flow Velocities Before and After the Hydraulic Jump:Upstream of the hydraulic jump, the effective flow velocity includes both the...
556