Related Experiment Video
Updated: Feb 8, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Outcomes of a Rapid Deployment Aortic Valve Versus Its Conventional Counterpart: A Propensity-Matched Analysis
Thorsten C W Wahlers, Martin Andreas1, Parwis Rahmanian
1Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.
Objective:
The aim of this study was to compare outcomes after rapid-deployment aortic valve replacement (RDAVR) and conventional aortic valve replacement (AVR) from two studies.
Methods:
Patients who underwent RDAVR (INTUITY valve) in the prospective, 5-year, single-arm multicenter TRITON study, or conventional AVR (Perimount Magna Ease valve) in the prospective Perimount Magna Ease postmarket study, were propensity score matched and compared for procedural, hemodynamic, safety, and clinical outcomes.
Results:
Matched RDAVR (n = 106) and conventional AVR (n = 106) patients had similar baseline characteristics (mean ± SD age, 72.8 ± 7.6 vs 72.5 ± 7.4 years; male 59.4% vs 61.3%) and procedures (concomitant procedures: 41.5% vs 50.9%). Mean ± SD aortic cross-clamp time was significantly shorter in RDAVR than AVR patients (51.8 ± 20.9 vs 73.9 ± 33.2 minutes; P < 0.001), as was mean cardiopulmonary bypass time (82.8 ± 34.2 vs 102.4 ± 41.7 minutes; P < 0.001). At 1 year, RDAVR patients showed significantly lower mean ± SD and peak aortic valve gradients (9.0 ± 3.4 and 17.0 ± 6.2 mm Hg, respectively) than conventional AVR patients (13.4 ± 5.5 and 24.2 ± 10.8 mm Hg, respectively; all P < 0.001). Patient-prosthesis mismatch was significantly less common with RDAVR than with AVR [overall: 16/66 (24.2%) vs 46/76 (60.5%); P = 0.007; severe: 2/66 (3.0%) vs 13/76 (17.1%)]. There were no significant differences between the RDAVR and AVR groups regarding 30-day safety endpoints. Survival rates in the RDAVR and conventional AVR groups were, respectively, 99.1% and 100.0% at 30 days, 97.1% and 95.1% at 1 year, and 93.3% and 94.1% at 3 years (P = nonsignificant).
Conclusions:
In this retrospective study with matched populations, the RDAVR with the INTUITY valve system provided superior procedural and hemodynamic outcomes than a standard bioprosthesis without compromising safety.
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Enolate Mechanism Conventions

