Related Experiment Video
Updated: Feb 8, 2026

Analysis of Fecal Microbiota Dynamics in Lupus-Prone Mice Using a Simple, Cost-Effective DNA Isolation Method
Published on: May 2, 2022
Balancing Adherence and Expense: The Cost-Effectiveness of Two-Sample vs One-Sample Fecal Immunochemical Test
David H Smith1, Maureen O'Keeffe Rosetti1, David M Mosen1
11 Center for Health Research , Kaiser Permanente Northwest, Portland, Oregon.
Abstract:
Colorectal cancer (CRC) causes more than 50,000 deaths each year in the United States but early detection through screening yields survival gains; those diagnosed with early stage disease have a 5-year survival greater than 90%, compared to 12% for those diagnosed with late stage disease. Using data from a large integrated health system, this study evaluates the cost-effectiveness of fecal immunochemical testing (FIT), a common CRC screening tool. A probabilistic decision-analytic model was used to examine the costs and outcomes of positive test results from a 1-FIT regimen compared with a 2-FIT regimen. The authors compared 5 diagnostic cutoffs of hemoglobin concentration for each test (for a total of 10 screening options). The principal outcome from the analysis was the cost per additional advanced neoplasia (AN) detected. The authors also estimated the number of cancers detected and life-years gained from detecting AN. The following costs were included: program management of the screening program, patient identification, FIT kits and their processing, and diagnostic colonoscopy following a positive FIT. Per-person costs ranged from $33 (1-FIT at 150ng/ml) to $92 (2-FIT at 50ng/ml) across screening options. Depending on willingness to pay, the 1-FIT 50 ng/ml and the 2-FIT 50 ng/ml are the dominant strategies with cost-effectiveness of $11,198 and $28,389, respectively, for an additional AN detected. The estimates of cancers avoided per 1000 screens ranged from 1.46 to 4.86, depending on the strategy and the assumptions of AN to cancer progression.
More Related Videos
04:57Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
Published on: April 25, 2025
07:55An All-in-one Sample Holder for Macromolecular X-ray Crystallography with Minimal Background Scattering
Published on: July 6, 2019
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Sampling Theorem
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
Sampling Distribution