Related Experiment Video
Updated: Feb 8, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Pulmonary Artery Catheter Placement Aided by Transesophageal Echocardiography versus Pressure Waveform Transduction
Brett Cronin1, Nikolai Kolotiniuk1, Kevin Youssefzadeh2
1Department of Anesthesiology, University of California, San Diego, UCSD Medical Center - Thornton Hospital, La Jolla, CA.
Objective:
To compare pulmonary artery catheter (PAC) placement by transesophageal echocardiography combined with pressure waveform transduction versus the traditional technique of pressure waveform transduction alone.
Design:
A prospective, randomized trial.
Setting:
Single university hospital.
Participants:
Forty-eight patients with chronic thromboembolic pulmonary hypertension (CTEPH) scheduled for pulmonary thromboendarterectomy.
Interventions:
PACs were placed in 48 patients with CTEPH scheduled for pulmonary thromboendarterectomy by either a combined approach (eg, transesophageal echocardiography [TEE] and pressure waveform transduction) or by pressure waveform transduction alone.
Measurements And Main Results:
Successful placement of the PAC via a combined technique or pressure waveform transduction alone was timed, number of attempts recorded, and final location noted. The final location of the pressure waveform-guided catheters was the proximal right pulmonary artery in 6 of 24 cases (25%), whereas the combined method resulted in successful placement in the proximal right pulmonary artery in 24 of 24 cases (100%). The pressure waveform technique resulted in a mean time to placement and mean number of attempts of 74 seconds and 1.70 attempts, respectively. The combined approach resulted in a mean time to placement and mean number of attempts of 89 seconds and 1.79 attempts, respectively. The combined method resulted in placement in the proximal right pulmonary artery significantly more often than the pressure-only method but did not reduce significantly the number of attempts or time required to place the catheter successfully. Additionally, among those cases that required more than 1 attempt or manipulation, there was no difference in the time to successful placement or the number of attempts required for successful placement.
Conclusion:
TEE guidance during PAC insertion was hypothesized to result in a higher success rate, precise placement, and shorter times to placement. One hundred percent of the PACs inserted with TEE guidance were positioned successfully in the proximal right pulmonary artery, which is the institutional preference. Although the combined technique resulted in greater precision, the clinical significance of this is unknown. The time to placement benefit was not confirmed by this study.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Phosphodiesterase Inhibitors
Among the PDE5 inhibitors, sildenafil (Revatio) stands out as a competitive and selective inhibitor. It operates by elevating cellular levels of cGMP and augmenting signaling through the cGMP-PKG pathway, promoting vasodilation. Upon oral...
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Transduction
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: