Introduction:
Despite various measures to protect against distal embolization during carotid artery stenting (CAS), periprocedural ischemic lesions are still encountered.
Objective:
To evaluate the periprocedural cerebral diffusion weighted imaging (DWI) lesion burden after CASPER stent placement.
Methods:
Patients who underwent CAS using the CASPER stent system were reviewed. Degrees of carotid stenosis and plaque configuration were determined. All patients were pretreated with dual antiplatelet agents and cerebral pre- and postprocedural MRI was obtained. All CAS procedures were performed by a single operator.
Results:
A total of 110 patients with severe carotid artery stenosis (median degree of stenosis 80%, median length of stenosis 10 mm) were treated with CAS. Hypoechogenic or heterogeneous, mostly hypoechogenic, plaques were documented in 48.6% (52/107) of patients. Carotid ulceration was present in 15.9% (17/107). Postprocedurally, 7.3% (8/110) of patients were found to have ischemic DWI lesions. They were asymptomatic in all patients. Follow-up at 90 days was available in 88.2% (97/110) of patients with excellent functional outcome (modified Rankin Scale score 0-1) in 95.9% (93/97).
Conclusion:
Carotid artery stenting using the new CASPER stent in combination with a distal embolic protection device is safe and results in a lower rate of periprocedural DWI lesion burden compared with reported results for historic controls.
More Related Videos
05:37Human Internal Mammary Artery IMA Transplantation and Stenting: A Human Model to Study the Development of In-Stent Restenosis
Published on: May 9, 2012
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Oxidation-Reduction Reactions
Oxymercuration-Reduction of Alkenes
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Phase I Reactions: Reductive Reactions
Esters to Alcohols: Hydride Reductions
Lithium aluminum hydride is a source of hydride ions and functions as a nucleophile. The mechanism proceeds in three steps. Firstly, the nucleophilic hydride ion attacks the carbonyl carbon of the ester to form a tetrahedral intermediate. Subsequently, the carbonyl group re-forms,...
Alcohols from Carbonyl Compounds: Reduction
Catalytic hydrogenation is similar to the reduction of an alkene or alkyne by adding H2 across the pi bond in the presence of transition metal catalysts like Raney Ni, Pd–C, Pt, or Ru. Aldehydes and ketones can be reduced by this method, often under mild to moderate heat (25–100°C) and...