Mechanical Structural Design of a Piezoresistive Pressure Sensor for Low-Pressure Measurement: A Computational
Anh Vang Tran1, Xianmin Zhang2, Benliang Zhu3
1Guangdong Key Laboratory of Precision Equipment and Manufacturing Technology, School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, China. vangtrananh@gmail.com.
Abstract:
This paper proposes a novel micro-electromechanical system (MEMS) piezoresistive pressure sensor with a four-petal membrane combined with narrow beams and a center boss (PMNBCB) for low-pressure measurements. The stresses induced in the piezoresistors and deflection of the membrane were calculated using the finite element method (FEM). The functions of the relationship between the dimension variables and mechanical performance were determined based on the curve fitting method, which can provide an approach for geometry optimization of the sensor. In addition, the values in the equations were varied to determine the optimal dimensions for the proposed membrane. Then, to further improve the sensitivity of the sensor, a series of rectangular grooves was created at the position of the piezoresistors. The proposed diaphragm was compared to existing diaphragms, and a considerable increase in the sensitivity and a considerable decrease in nonlinearity error could be achieved by using the proposed sensor. The simulation results suggest that the sensor with the PMNBCB structure obtained a high sensitivity of 34.67 mV/kPa and a low nonlinearity error of 0.23% full-scale span (FSS) for the pressure range of 0⁻5 kPa. The proposed sensor structure is a suitable selection for MEMS piezoresistive pressure sensors.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Vapor Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Constant Pressure Calorimetry