Related Experiment Video
Updated: Feb 8, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
An in vitro evaluation of laser settings and location in the efficiency of the popcorn effect
Daniel A Wollin1, Westin R Tom2, Ruiyang Jiang3
1Division of Urologic Surgery, Duke University Medical Center, Durham, NC, USA. daniel.wollin@duke.edu.
Abstract:
To examine different locations and laser settings' effects on the efficiency of the "popcorn" method of laser lithotripsy, which consists of placing the laser in a group of small stones and firing continuously to break them into smaller particles. Pre-fragmented BegoStones were created between 2 and 4 mm to mimic typical popcorning conditions. A 0.5 g collection of fragments was placed into 3D-printed models (a spherical calyx and ellipsoid pelvis model) and a 200-µm laser fiber was positioned above the stones. The laser was fired for 2 min with irrigation, with 5 trials at each setting: 0.2 J/50 Hz, 0.5 J/20 Hz, 0.5 J/40 Hz, 1 J/20 Hz, 0.2 J/80 Hz, 0.5 J/80 Hz. After drying, fragmentation efficiency was determined by calculating the mass of stones reduced to sub-2 mm particles. Statistical analysis was performed with ANOVA and Student's t test. The trials within the calyx model were significantly more efficient compared to the pelvis (0.19 vs 0.15 g, p = 0.01). When comparing laser settings, there was a difference between groups by one-way ANOVA [F(5,54) = 8.503, p = 5.47 × 10-6]. Post hoc tests showed a power setting of 0.5 J/80 Hz was significantly more efficient than low-power settings 0.2 J/50 Hz and 0.5 J/20 Hz (p < 0.05). Additionally, 0.2 J/50 Hz was significantly less efficient than 0.5 J/40 Hz, 1 J/20 Hz, and 0.2 J/80 Hz. Popcorning is most efficient in smaller spaces; we recommend displacement of stones into a calyx before popcorning. No difference was seen between high-power settings, although 0.5 J/40 Hz and 0.5 J/80 Hz performed best, suggesting that moderate energy popcorning methods with at least 0.5 J per pulse are most efficient.
Related Concept Videos
Location and Orientation of the Heart
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
Selected Data About Geographic Locations
Olfactory Receptors: Location and Structure
Setting Time of Cement
Specialized Care Centers and Settings-II
Rural health centers are specialized care facilities in remote locations with very few medical personnel. The primary care providers who run the centers are mostly Registered Nurse Practitioners. Here, emergency treatment is provided to critically ill or injured patients before they are transferred to the closest hospital. Fortunately, due to advancement in technology, many rural healthcare facilities and professionals have easy access to diagnostic and treatment...

