Subclinical cardiac perforation caused by a Micra™ leadless pacemaker
Ikuko Togashi1, Toshiaki Sato2, Kyoko Hoshida1
1Cardiology Kyorin University School of Medicine Mitaka Japan.
A rare complication of Micra™ transcatheter pacing system, cardiac perforation, was identified. Careful review of imaging before deployment is crucial to prevent this serious adverse event.
Area of Science:
- Cardiology
- Medical Devices
- Cardiac Imaging
Background:
- The Micra™ transcatheter pacing system offers a leadless solution for cardiac pacing.
- Device placement involves positioning the cup on the right ventricular septum.
Observation:
- Subclinical cardiac perforation occurred during Micra™ implantation.
- Contrast media injection revealed contrast outside the myocardium, within the pericardium.
- Cardiac CT identified a diverticular structure on the right ventricle.
Findings:
- The Micra™ device cup perforated the right ventricle.
- Contrast material extravasated into the pericardial space.
- A diverticular structure was noted on the right ventricle.
Implications:
- This case highlights a potential risk associated with Micra™ transcatheter pacing.
- Careful pre-deployment imaging review, particularly the right anterior oblique view, is essential.
- Ensuring proper device orientation away from the septum-free wall border can prevent perforation.
More Related Videos
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...