Effect of high-intensity curing lights on the polymerization of bulk-fill composites
Mindy M Daugherty1, Wen Lien2, Michael R Mansell1
1United States Army, 36014 Wratten Loop, Ft. Hood, TX 76544, USA.
Objectives:
The purpose of this study was to investigate the effect of high-irradiance light-curing-units (LCUs) on the depth-of-cure (DoC) and degree-of-polymerization (DoP) of bulk-fill composites (BFCs).
Methods:
The DoC of composites (Beautifil-Bulk, SHOFU; Filtek-Bulk-Fill, 3M ESPE; Tetric-EvoCeram-Bulk-Fill, Ivoclar; Sonic-Fill-2, Kerr; Venus-Bulk-Fill, Heraeus; Z250, 3M-ESPE) were measured according to ISO-4049 using high-irradiance LCUs (FlashMax-P3, CMS-Dental; SPEC3, Coltene) and conventional LCU (Paradigm, 3M-ESPE) for exposure times: 3/9-s, 3/20-s, and 10/20-s respectively. Using FTIR, the DoP per composite was measured at the bottom surface as a function of post-curing times for the LCUs at the same exposure times. Data was analyzed with nonlinear regression and ANOVA/Tukey.
Results:
Significant differences in DoC were found amongst the LCUs for the various exposure times. All BFCs failed to meet the DoC claimed by manufacturers and failed to satisfy ISO-4049 with the high-irradiance LCUs with 3-s exposures. Standard irradiance and 20-s exposures outperformed all other irradiance-exposure combinations for maximizing the DoC and DoP of BFCs. A minimum of 15.3J/cm2 radiant exposure was required to achieve an adequate maximum polymerization rate. Venus Bulk exhibited the highest DoC and DoP for any LCU-exposure-time combination.
Significance:
Among the different combinations of BFCs and LCUs, DoC and DoP were always increased with longer exposure time, but there exists a theoretical radiant-exposure limit beyond which DoP or DoC remains unchanged. However, high DoC or DoP are not always associated with one another. Thus, the exposure-reciprocity law must be approached thoughtfully since irradiance and exposure can independently affect DoP and DoC.
More Related Videos
07:39Facile Synthesis of Worm-like Micelles by Visible Light Mediated Dispersion Polymerization Using Photoredox Catalyst
Published on: June 8, 2016
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
Related Concept Videos
Curing of Concrete
Curing Methods
Accelerated Curing of Concrete
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Bulk Modulus
Sound Intensity