Comparative Study of Positron Emission Tomography/Computed Tomography and Computed Tomography in the Evaluation of
Saurabh Pantola1, Sanjay Kala2, Chayanika Kala3
1Department of Radiodiagnosis, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India.
Purpose Of Study:
To evaluate and compare imaging findings using computed tomography (CT) alone and positron emission tomography/CT (PET/CT) fusion imaging in posttreatment carcinoma cervix patients for recurrence.
Subjects And Methods:
From June 2014 to May 2016, 50 posttreatment carcinoma cervix patients were referred to our institution for PET/CT imaging. In all 50 of these patients referred for evaluation, a reliable reference standard was available. The reference standard was established by histopathological examination of accessible locoregional and nodal/distant metastatic involvement or follow-up of patients. CT and PET/CT were performed and analyzed for locoregional, pelvic nodal, and distant metastasis involvement in posttreatment carcinoma cervix cases.
Results:
In the evaluation of locoregional involvement, CT alone was found to have a sensitivity of 75% and specificity of 90% while PET/CT was found to have a sensitivity of 95% and specificity of 100%. Furthermore, in evaluation of pelvic nodal involvement, CT alone was found to have a sensitivity of 72% and specificity of 92.6% while PET/CT was found to have a sensitivity of 95.5% and specificity of 92.9%. In context to distant metastasis involvement (including para-aortic nodes), CT alone was found to have a sensitivity of 91.7% and specificity of 96.2% while PET/CT was found to have a sensitivity of 95.8% and specificity of 100%. PET/CT fusion in comparison to CT alone is better in sensitivity and specificity in the detection of locoregional involvement, pelvic node invasion, and distant metastasis in posttreatment carcinoma cervix cases.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations