Related Experiment Video
Updated: Feb 8, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
First fully automated planning solution for robotic radiosurgery - comparison with automatically planned volumetric
Linda Rossi1, Abdul Wahab Sharfo1, Shafak Aluwini1
1a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , The Netherlands.
Background:
For conventional radiotherapy treatment units, automated planning can significantly improve plan quality. For robotic radiosurgery, systems for automatic generation of clinically deliverable plans do not yet exist. For prostate stereotactic body radiation therapy (SBRT), few studies have systematically compared VMAT with robotic treatment.
Material And Methods:
The multi-criteria autoplanning optimizer, developed at our institute, was coupled to the commercial treatment planning system of our robotic treatment unit, for fully automated generation of clinically deliverable plans (autoROBOT). The system was then validated by comparing autoROBOT plans with manually generated plans. Next, the autoROBOT system was used for systematic comparisons between autoROBOT plans and VMAT plans, that were also automatically generated (autoVMAT). CTV-PTV margins of 3 mm were used for autoROBOT (clinical routine) and autoVMAT plan generation. For autoVMAT, an extra plan was generated with 5 mm margin (often applied for VMAT). Plans were generated for a 4 × 9.5 Gy fractionation scheme.
Results:
Compared to manual planning, autoROBOT improved rectum D[Formula: see text] (16%), V[Formula: see text] (75%) and D[Formula: see text] (41%), and bladder D[Formula: see text] (37%) (all p [Formula: see text] .002), with equal PTV coverage. In the autoROBOT and autoVMAT comparison, both with 3 mm margin, rectum doses were lower for autoROBOT by 5% for rectum D[Formula: see text] (p=.002), 33% for V[Formula: see text] (p=.001) and 4% for D[Formula: see text] (p=.05), with comparable PTV coverage and other OAR sparing. With 5 mm margin for VMAT, 18/20 plans had a PTV coverage lower than requested (<95%) and all plans had higher rectum doses than autoROBOT (mean percentage differences of 13% for D[Formula: see text], 69% for V[Formula: see text] and 32% for D[Formula: see text] (all p<.001)).
Conclusions:
The first system for fully automated generation of clinically deliverable robotic plans was built. Autoplanning did largely enhance robotic plan quality, compared to manual planning. Using autoplanning for both the robotic system and VMAT, superiority of non-coplanar robotic treatment compared to coplanar VMAT for prostate SBRT was demonstrated.
Related Concept Videos
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Planning Nursing Care I
Planning Nursing Care II
Role of Communication in the Nursing Process II: Planning and Implementation
Nursing Process for Patient and Caregiver Teaching II: Planning and Implementation
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...

