Related Experiment Video
Updated: Feb 8, 2026

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Irradiance and Radiant Exposures Delivered by LED Light-Curing Units Used by a Left and Right-Handed Operator
Carlos José Soares1, Gabriel Felipe de Bragança1, Renata Afonso da Silva Pereira1
1Department of Operative Dentistry and Dental Materials, Dental School, UFU - Universidade Federal de Uberlândia, Uberlândia, MG, Brazil.
Abstract:
The combination of the restoration location, the hand preference of the operator using the light-curing unit (LCU), and the design of the LCU all can have an impact on the amount of the light delivered to the restoration. To evaluate the effect of left-handed or right-handed users, the position of the operator (dentist or assistant), and the LCU design on the irradiance, radiant exposure and emission spectrum delivered to the same posterior tooth. Two light emitting diode (LED) LCUs were tested: an angulated monowave LCU Radii-Cal (SDI, Victoria, Australia) and a straight aligned multi-peak LCU Valo Cordless (Ultradent, South Jordan, UT, USA). The irradiance values (mW/cm2), radiant exposure (J/cm2) and emission spectrum were measured using a sensor in maxillary left second molar tooth. The irradiance and radiant exposure were analyzed using three-way ANOVA followed by Tukey test (a=0.05). The emission spectra (nm) were analyzed descriptively. The interaction between LCU design, operator position, and hand preference significantly influenced the irradiance and radiant exposure (P<0.001). In all cases, Valo delivered significantly higher irradiance than Radii-Cal. The handedness and the operator position affected the irradiance and radiant exposure delivered from Valo. Operator position and access affect the irradiance and radiant exposure delivered to the maxillary left second molar. The irradiance and radiant exposure can be greater when a right-hand operator is positioned on the right side of the chair and a left-hand operator is positioned on the left side of the chair. This may result in better resin composite polymerization.
More Related Videos
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
08:58Preparing Irradiated and Marked Male Aedes aegypti Mosquitoes for Release in an Operational Sterile Insect Technique Program
Published on: March 12, 2021
Related Concept Videos
Curing of Concrete
Curing Methods
Measurement: Derived Units
Accelerated Curing of Concrete
Measurement: Standard Units
Hand hygiene
Hand washing...