Related Experiment Video
Updated: Feb 8, 2026

Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Sheathless coupling of microchip electrophoresis to ESI-MS utilising an integrated photo polymerised membrane for
T Scholl1, C Dietze1, M Schmidt1
1Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
Abstract:
In this article, we present a novel approach for the sheathless coupling of microchip electrophoresis (MCE) with electrospray mass spectrometry (ESI-MS). The key element is an ion-conductive hydrogel membrane, placed between the separation channel and an adjacent microfluidic supporting channel, contacted via platinum electrodes. This solves the persistent challenge in hyphenation of mass spectrometry to chip electrophoresis, to ensure a reliable electrical connection at the end of the electrophoresis channel without sacrificing separation performance and sensitivity. Stable electric contacting is achieved via a Y-shaped supporting channel structure, separated from the main channel by a photo polymerised, ion permeable hydrogel membrane. Thus, the potential gradient required for performing electrophoretic separations can be generated while simultaneously preventing gas formation due to electrolysis. In contrast to conventional make-up or sheathflow approaches, sample dilution is also avoided. Rapid prototyping allowed the study of different chip-based approaches, i.e. sheathless, open sheathflow and electrode support channel designs, for coupling MCE to ESI-MS. The performance was evaluated with fluorescence microscopy and mass spectrometric detection. The obtained results revealed that the detection sensitivity obtained in such Y-channel chips with integrated hydrogel membranes was superior because sample dilution or loss was prevented. Furthermore, band broadening is reduced compared to similar open structures without a membrane.
More Related Videos
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
05:47Preparation of Polyoxometalate-based Photo-responsive Membranes for the Photo-activation of Manganese Oxide Catalysts
Published on: August 7, 2018
Related Concept Videos
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
G-protein Coupled Receptors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Introduction to Membrane Proteins
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...