Integrated Field Lysimetry and Porewater Sampling for Evaluation of Chemical Mobility in Soils and Established Vegetation
Published on: July 4, 2014
Evaluation of passive sampling polymers and nonequilibrium adjustment methods in a multiyear surveillance of sediment
James P Sanders1, Natasha A Andrade1, Upal Ghosh1
1Department of Chemical, Biochemical, and Environmental Engineering, University of Maryland, Baltimore County, Baltimore, Maryland, USA.
Abstract:
Polymeric passive sampling devices are increasingly used to measure low-level, freely dissolved concentrations of hydrophobic organic contaminants in environmental waters. A range of polymers have been used for this purpose, and several different methods of accounting for nonequilibrium using performance reference compounds (PRCs) have been proposed. The present study explores the practical impacts of these decisions in an applied context using results from a multiyear passive sampling surveillance of polychlorinated biphenyl concentrations in sediment porewater at a contaminated marsh amended with activated carbon (AC) sorbent materials. In a series of 5 sampling events spanning almost 2 yr, we deployed polyoxymethylene and polyethylene samplers and calculated porewater concentrations with 5 different PRC adjustment methods. The results provide a basis for evaluating amendment performance by showing reductions of 34 to 97% in amended sediment porewater concentrations. They also provide a quantitative underpinning for discussions of the differences between sampling polymers, selection of PRCs, generation of high-resolution vertical profiles of porewater concentrations, and a comparison of PRC adjustment methods. For unamended sediment, older methods based on first-order kinetics agreed well with a recently developed method based on diffusion into and out of sediment beds. However, the sediment diffusion method did not work well for the sediments amended with AC. Environ Toxicol Chem 2018;37:2487-2495. © 2018 SETAC.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
12:15A Flow-through Exposure System for Evaluating Suspended Sediments Effects on Aquatic Life
Published on: January 9, 2017
Related Concept Videos
Polymers
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
The Anchoring-and-Adjustment Heuristic
Adjusting a Traverse
Principles of Disease Surveillance
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...