Related Experiment Video
Updated: Feb 8, 2026

Nerve Ultrasound Protocol to Detect Dysimmune Neuropathies
Published on: October 7, 2021
Simple presurgical method of predicting C5 palsy after cervical laminoplasty using C5 nerve root ultrasonography
Mikinobu Takeuchi1,2,3, Norimitsu Wakao1,4, Mitsuhiro Kamiya1,4
11Spine Center.
Objective:
The incidence of C5 palsy after cervical laminoplasty is approximately 5%. Because C5 palsy is related to cervical foraminal stenosis at the C4-5 level, the authors hypothesized that cervical foraminal stenosis can be diagnosed by examining the C5 nerve root (NR) using ultrasonography. The purpose of this study was to investigate whether postoperative C5 palsy could be predicted using ultrasonography.
Methods:
This study used a prospective diagnosis design. In total, 140 patients undergoing cervical laminoplasty were examined with ultrasound. The cross-sectional area (CSA) of the C5 NR was measured on both sides before surgery, and the incidence of postoperative C5 palsy was examined. The difference between the CSA of the patients with and without C5 palsy and the lateral differences in the C5 palsy group were determined.
Results:
The incidence of C5 palsy was 5% (7 cases). Symptoms manifested at a median of 5 days after surgery (range 1-29 days). The CSA of the C5 NR on the affected side was significantly enlarged in the C5 palsy group compared with that in the no-C5 palsy group (p = 0.001). In addition, in the patients who had C5 palsy, the CSA of the C5 NR was significantly enlarged on the affected side compared with that on the unaffected side (p = 0.02). Receiver operating characteristic analysis indicated that the best threshold value for the CSA of the C5 NR was 10.4 mm2, which provided 91% sensitivity and 71% specificity.
Conclusions:
C5 palsy may be predicted preoperatively using ultrasound. The authors recommend the ultrasonographic measurement of the CSA of the C5 NR prior to cervical laminoplasty.
More Related Videos
06:48Ethanol-Induced Cervical Sympathetic Ganglion Block Applications for Promoting Canine Inferior Alveolar Nerve Regeneration Using an Artificial Nerve
Published on: November 30, 2018
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Root-Locus Method
This system can be represented by a block...
Predicting Molecular Geometry
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.