Related Experiment Video
Updated: Feb 8, 2026

Fused Filament Fabrication FFF of Metal-Ceramic Components
Published on: January 11, 2019
Effect of cyclic bend loading on a cobalt-chromium clasp fabricated by direct metal laser sintering
Soo Yeop Kim1, Soo-Yeon Shin2, Jong Hyuk Lee2
1Postgraduate student, Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea.
Statement Of Problem:
Limited information is available regarding the mechanical properties of a partial removable dental prosthesis clasp fabricated by direct metal laser sintering (DMLS).
Purpose:
The purpose of this in vitro study was to measure the mechanical properties of cast clasps, DMLS clasps, and annealed DMLS clasps and to determine the correlation between cyclic bend loading, annealing, and mechanical properties.
Material And Methods:
Sixty half round clasp specimens were fabricated, with a length of 20 mm and a diameter of 1.5 mm at 10 mm from the tip. The specimens were divided into 6 groups (n=10). Twenty specimens were fabricated by casting (CS, CSAC), and 40 specimens were fabricated by DMLS (DS, DSAC, ADS, ADSAC). Of the DMLS specimens, 20 underwent annealing (ADS, ADSAC). Equivalent to 5 years of clinical use, 0.25 mm of bending was applied to group CSAC, DSAC, and ADSAC 14 600 times. After cyclic bending loads, a cantilever bend test was conducted on all groups, and the loads were measured. To compare the load values, 1-way ANOVA and the Tukey HSD test were performed and statistical significance among the groups was evaluated (α=.05). Scanning electron microscopy and energy-dispersive spectroscopy analyses were also used for surface morphology evaluation and element analysis.
Results:
Bending loads of the DMLS specimens were significantly lower than those of the cast specimens (P<.05). The influence of cyclic bending loads was significant for cast specimens (P<.05), but not for DMLS specimens (P>.05), in terms of variation of loads. Annealed DMLS specimens had significantly higher bending loads than DMLS specimens (P<.05).
Conclusions:
The DMLS specimens had lower load values at 0.25 mm bending than cast specimens. The DMLS specimens were less influenced by cyclic bending loads than the cast specimens. Annealing increased load values of the DMLS specimens at 0.25 mm bending.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
11:09Scalable Solution-processed Fabrication Strategy for High-performance, Flexible, Transparent Electrodes with Embedded Metal Mesh
Published on: June 23, 2017
Related Concept Videos
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Properties of Transition Metals
Bending
In pure bending, the bending stress in a beam is calculated based on the bending moment and...
Bonding in Metals
Symmetric Member in Bending