Related Experiment Video
Updated: Feb 8, 2026

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Extended compatibility of fentanyl and ketamine in dextrose 5
Suci Hanifah1, Ross Kennedy, Patrick Ball
1Department of Pharmacy, Faculty of Science, Universitas Islam Indonesia, Yogyakarta, Indonesia. suci.hanifah@gmail.com.
Background:
There are no published studies that report on fentanyl and ketamine compatibility in dextrose 5% solution as commonly practiced in hospital settings.
Methods:
This study assessed the compatibility of fentanyl and ketamine after their reconstitution in dextrose 5% under ambient temperature and humidity conditions in a hospital setting. Each sample of fentanyl and ketamine was prepared in triplicate by adding dextrose 5% to a prefilled syringe until final concentrations of 9.8 μg mL-1 for fentanyl and 192 μg mL-1 for ketamine were achieved. The solutions were stored in syringes at an ambient temperature ranging 26-28°C either under a mixture of daylight and ambient lighting. A sample was taken from the syringes at the following times: 0, 8, 24, 72, 120, and 168 hours. The samples from each solution were checked for physical changes, pH and their concentration assessed by high-performance liquid chromatography.
Results:
The solutions were clear and no physical changes were seen. The pH of fentanyl and ketamine decreased dramatically after 72 hours. The concentrations of fentanyl remained 90-110% only for 24 hours, while ketamine remained 90-110% for 168 hours.
Conclusion:
Solutions of fentanyl and ketamine in dextrose 5% may be used in prefilled syringes only up to 24 hours and 72 hours after reconstitution, respectively.
More Related Videos
05:25Author Spotlight: Evaluating Therapeutic Strategies to Enhance Liver Regeneration
Published on: May 24, 2024
07:12Determination of Self-Incompatibility and Inter-Incompatibility Relationships in Citrus Using Manual Pollination, Microscopy, and S-Genotype Analyses
Published on: June 30, 2023
Related Concept Videos
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Gravitational Potential Energy for Extended Objects
Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists
Electrolytes: van't Hoff Factor
The colligative properties of a solution depend only on the number, not on the identity, of solute species dissolved. The concentration terms in the equations for various colligative properties (freezing point depression, boiling point elevation, osmotic pressure) pertain to all solute species present in the solution. Nonelectrolytes dissolve physically without dissociation or any other accompanying process. Each molecule that dissolves yields one...
Reliability and Validity
Electron Configuration of Multielectron Atoms