BOLD cardiac MRI for differentiating reversible and irreversible myocardial damage in ST segment elevation myocardial

Bing-Hua Chen1, Ruo-Yang Shi1, Dong-Aolei An1

  • 1Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China.

European Radiology
|July 11, 2018
PubMed
Abstract

Related Concept Videos

Reversible and Irreversible Processes01:14

Reversible and Irreversible Processes

The thermodynamic processes can be classified into reversible and irreversible processes. The processes that can be restored to their initial state are called reversible processes. It is only possible if the process is in quasi-static equilibrium, i.e., it takes place in infinitesimally small steps, and the system remains at equilibrium However, these are ideal processes and do not occur naturally. An ideal system undergoing a reversible process is always in thermodynamic equilibrium within...
5.8K
Freezing Point Depression and Boiling Point Elevation03:12

Freezing Point Depression and Boiling Point Elevation

Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
40.3K
Elevation of Intermediate Points on Vertical Curves01:20

Elevation of Intermediate Points on Vertical Curves

Vertical curves are essential in roadway design because they provide smooth transitions between varying roadway grades. Designing vertical curves involves calculating intermediate elevations and identifying the curve's highest or lowest point, which is essential for optimal roadway performance.Intermediate elevations on a vertical curve are determined using the tangent offset method. This method considers the initial elevation at the start of the curve, the grades, and the curve's geometry. The...
308
Diode: Reverse bias01:14

Diode: Reverse bias

A diode is reverse-biased when the positive terminal of an external voltage source is connected to the n-type material and the negative terminal to the p-type material. This configuration opposes the natural direction of current flow through the diode, effectively increasing the width of the depletion region and the barrier potential. The reverse bias condition produces a minimal leakage current, primarily due to minority charge carriers. This leakage becomes significant when the reverse...
2.0K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
903
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
3.5K