Related Experiment Video
Updated: Feb 8, 2026

The Intra-Aortic Balloon Pump
Published on: February 5, 2021
[How to choose between intra-aortic balloon pump, Impella and extracorporeal membrane oxygenation]
Francesco Burzotta1, Giulio Russo1, Eloisa Basile1
1Istituto di Cardiologia, Università Cattolica del Sacro Cuore, Policlinico Universitario A. Gemelli, Roma.
Abstract:
The use of percutaneous mechanical circulatory support systems in the setting of both high-risk percutaneous coronary intervention (PCI) and cardiogenic shock is an emerging, controversial issue in contemporary clinical cardiology. The most common devices are the intra-aortic balloon pump (IABP), the Impella and the extracorporeal membrane oxygenator (ECMO). Technical progress, equipment improvement and growing cath-lab team expertise are allowing to offer critical patients different levels of assistance according to the selected device. Indeed, they are extremely different and the selection of the proper device for each clinical scenario might be tricky. In high-risk PCI, mechanical hemodynamic support serves the purpose of preventing hemodynamic collapse during the procedure. According to baseline risk stratification, IABP or Impella are usually considered whereas ECMO is seldom considered as a third option for highly selected patients.Cardiogenic shock and cardiac arrest are still associated with high mortality rates. In these conditions mechanical support may be promising. The lack of benefit observed with the systematic use of the IABP (combined with the increased mortality associated with higher number of inotropic drugs) is actually prompting to increasingly consider Impella and ECMO use in critically ill patients. The development of multidisciplinary local protocols is considered pivotal to improve management and outcome of those patients requiring percutaneous circulatory support devices.
Related Concept Videos
Choosing Between z and t Distribution
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration

