Published on: June 17, 2013
Removal of High-Voltage Brain Stimulation Artifacts From Simultaneous EEG Recordings
Objective:
noninvasive electrical brain stimulation (NEBS) can modulate brain dynamics and be used to induce changes in target brain areas. Because high-voltage stimulation artifacts tend to completely dominate the simultaneously recorded EEG and vary slightly trial by trial in both amplitude and phase, the majority of studies to date have simply compared poststimulation and prestimulation periods. Here, we propose the use of a modified joint blind source separation (JBSS) approach for removing stimulation artifacts when the same stimulus is applied in multiple epochs.
Methods:
quadrature regression and subsequent independent vector analysis (q-IVA) was applied to simulated and real EEG datasets recorded from ten subjects who received theta-band galvanic vestibular stimulation.
Results:
in simulations, q-IVA and JBSS approaches significantly improved the relative root-mean-squared error, correlation coefficient, and power deviation between the original and recovered EEG compared to conventional methods. In the real EEG data, after removing the artifacts with q-IVA, the power spectra during stimulation demonstrated significantly enhanced beta and gamma power compared to prestimulation, becoming similar to that seen in immediate poststimulation periods. In addition, we demonstrate that increased alpha power (8-13 Hz) in occipital regions with eye closure could be reliably detected in the cleaned EEG data after applying q-IVA.
Conclusion:
q-IVA and JBSS approaches outperform conventional artifact removal methods in both time and frequency domains.
Significance:
our results provide a promising way to effectively isolate stimulation artifacts in EEG, paving the way for future studies attempting to uncover ongoing modulation of brain activity during NEBS.
More Related Videos
10:35Best Current Practice for Obtaining High Quality EEG Data During Simultaneous fMRI
Published on: June 3, 2013
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
Related Concept Videos
Voltage
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Voltage Dividers
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
Three-Phase Voltages
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...