Model-Based Assessment of f-Wave Signal Quality in Patients With Atrial Fibrillation
Objective:
The detection and analysis of atrial fibrillation (AF) in the ECG is greatly influenced by signal quality. The present study proposes and evaluates a model-based f-wave signal quality index (SQI), denoted , for use in the QRST-cancelled ECG signal.
Methods:
is computed using a harmonic f-wave model, allowing for variation in frequency and amplitude. The properties of are evaluated on both f-waves and P-waves using 378 12-lead ECGs, 1875 single-lead ECGs, and simulated signals.
Results:
decreases monotonically when noise is added to f-wave signals, even for noise which overlaps spectrally with f-waves. Moreover, is shown to be closely associated with the accuracy of AF frequency estimation, where implies accurate estimation. When is used as a measure of f-wave presence, AF detection performance improves: the sensitivity increases from 97.0% to 98.1% and the specificity increases from 97.4% to 97.8% when compared to the reference detector.
Conclusion:
The proposed SQI represents a novel approach to assessing f-wave signal quality, as well as to determining whether f-waves are present.
Significance:
The use of improves the detection of AF and benefits the analysis of noisy ECGs.
More Related Videos
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
The Wave Nature of Light
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Small-signal Diode Model
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...