Related Experiment Video
Updated: Feb 7, 2026

Measurement of the Compressibility of Cell and Nucleus Based on Acoustofluidic Microdevice
Published on: July 14, 2022
Low-Complexity Privacy-Preserving Compressive Analysis Using Subspace-Based Dictionary for ECG Telemonitoring System
Abstract:
Compressive sensing (CS) is attractive in long-term electrocardiography (ECG) telemonitoring to extend life-time for resource-constrained wireless wearable sensors. However, the availability of transmitted personal information has posed great concerns for potential privacy leakage. Moreover, the traditional CS-based security frameworks focus on secured signal recovery instead of privacy-preserving data analytics; hence, they provide only computational secrecy and have impractically high complexities for decryption. In this paper, to protect privacy from an information-theoretic perspective while delivering the classification capability, we propose a low-complexity framework of Privacy-Preserving Compressive Analysis (PPCA) based on subspace-based representation. The subspace-based dictionary is used for both encrypting and decoding the CS measurements online, and it is built by dividing signal space into discriminative and complementary subspace offline. The encrypted signal is unreconstructable even if the eavesdropper cracks the measurement matrix and the dictionary. PPCA is implemented in ECG-based atrial fibrillation detection. It can reduce the mutual information by 1.98 bits via encrypting measurements with signal-dependent noise at 1 dB, while the classification accuracy remains 96.05% with the decoding matrix. Furthermore, by decoding via matrix-vector product, rather than sparse coding, this computational complexity of PPCA is 341 times fewer compared with the traditional CS-based security.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Formation of Complex Ions