Related Experiment Video
Updated: Feb 7, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Post cardiac surgery stunning reduces stroke work, but leaves cardiac power output unchanged in patients with normal
Tomas D Tannvik1,2, Audun E Rimehaug1, Nils K Skjaervold1,2
1Department of Anaesthesia and Intensive Care, St Olav's Hospital, Trondheim University Hospital, Trondheim, Norway.
Insights
Cardiac power output remained stable after coronary artery bypass graft surgery, unlike stroke work, which decreased, indicating stroke work may better detect temporary cardiac dysfunction.
Area of Science:
- Cardiovascular Physiology
- Cardiac Surgery Outcomes
Background:
- Assessing hemodynamic changes after coronary artery bypass graft (CABG) surgery is crucial for understanding cardiac recovery.
- Classic hemodynamic variables and newer metrics like cardiac power output (CPO) and stroke work (SW) require comparative analysis.
Purpose of the Study:
- To evaluate positional changes in CPO and SW compared to traditional hemodynamic variables.
- To determine if CPO is altered in relation to cardiac stunning post-CABG surgery.
Main Methods:
- Retrospective analysis of data from 36 patients undergoing elective CABG surgery.
- Inclusion of patients with preserved left ventricular function.
- Measurement of hemodynamic parameters, CPO, and SW using pulmonary and radial artery catheters pre- and postoperatively, in supine and standing positions.
Main Results:
- Systemic hemodynamic parameters significantly changed from pre- to postoperatively and with positional changes.
- Cardiac power output (CPO) remained consistently maintained (0.9-1.0 W) across all conditions.
- Stroke work (SW) significantly decreased postoperatively and with positional changes, indicating greater sensitivity to cardiovascular dysfunction.
Conclusions:
- Stroke work (SW) appears to be a more sensitive indicator of temporary cardiovascular dysfunction than cardiac power output (CPO) after CABG.
- CPO was the sole hemodynamic variable that remained unaltered throughout positional and temporal changes.
- Further research is warranted to explore the autoregulation of CPO and its relationship with cardiac performance.
Abstract:
This study assesses positional changes in cardiac power output and stroke work compared with classic hemodynamic variables, measured before and after elective coronary artery bypass graft surgery. The hypothesis was that cardiac power output was altered in relation to cardiac stunning. The study is a retrospective analysis of data from two previous studies performed in a tertiary care university hospital. Thirty-six patients scheduled for elective coronary artery bypass graft surgery, with relatively preserved left ventricular function, were included. A pulmonary artery catheter and a radial artery catheter were placed preoperatively. Cardiac power output and stroke work were calculated through thermodilution both supine and standing prior to induction of anesthesia and again day one postoperatively. Virtually all systemic hemodynamic parameters changed significantly from pre- to postoperatively, and from supine to standing. Cardiac power output was maintained at 0.9-1.0 (±0.3) W both pre- and postoperatively and from supine to standing on both days. Stroke work fell from pre- to postoperatively from 1.1 to 0.8 J (P < 0.001), there was a significant fall in stroke work with positional change preoperatively from 1.1 to 0.9 J (P < 0.001). Postoperatively the stroke work remained at 0.8 J despite positional change. Cardiac power output was the only systemic hemodynamic variable which remained unaltered during all changes. Stroke work appears to be a more sensitive marker for temporary cardiovascular dysfunction than cardiac power output. Further studies should explore the relationship between stroke work and cardiac performance and whether cardiac power output is an autoregulated intrinsic physiological parameter.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Electrophysiology of Normal Cardiac Rhythm

