Quantification of skin stiffness in patients with systemic sclerosis using real-time shear wave elastography: a
Yujia Yang1, Feng Yan2, Liyun Wang1
1Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, China.
Objectives:
To assess the diagnostic value of shear wave elastography (SWE) quantification in patients with systemic sclerosis (SSc) and healthy controls.
Methods:
Skin elastic modulus (E) values and thicknesses were measured at 6 skin sites between the SSc (n=37) and control (n=37) groups. Thickness and E values were converted into T- and E-scores, to allow skin thickness and stiffness of different regions to be quantified based on a single standard. T- and E-scores were compared with the modified Rodnan skin score (mRSS).
Results:
E values were significantly higher in SSc patients than healthy controls at all measured sites (p<0.001), whereas skin thickness increased significantly only at fingers and forearms (p<0.001). E-score analysis revealed mRSS differences within 1.0 at most sites, while T- score evaluation only showed differences between mRSS 0 and mRSS 1 at fingers. Interestingly, mRSS correlated more closely with skin stiffness (r=0.889, p<0.001) than skin thickness (r=0.465, p=0.002).
Conclusions:
In patients with SSc, SWE is more sensitive to detect subtle skin changes than B-mode ultrasound (US), and reflect the degree of skin involvement. As a non-invasive and operator-independent technique, SWE may provide a new and valuable method to evaluate the degree and changes of skin involvement in SSc patients.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
12:18Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
Related Concept Videos
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
The Wave Nature of Light
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.