[Contrast-enhanced spectral mammography. Experience in 465 examinations]
María E Navarro1, Dravna Razmilic1, Isabel Araos1
1Departamento de Radiología, Escuela de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.
Background:
Contrast-enhanced spectral mammography or "contrast mammography" has a better cost effectiveness than breast magnetic resonance for confirmation of suspicious lesions detected on breast screening programs.
Aim:
To report the experience of a single center in Santiago.
Material And Methods:
All patients referred for contrast mammography between July 2015 and October 2017 were studied. We recorded the patient risk factors for breast cancer. In 85 patients with suspicious lesions, biopsy results were available.
Results:
We analyzed 465 contrast mammographies. The most common clinical indications were suspicion of cancer and previous inconclusive studies. Mass type lesions were detected in 33% of the studies. Non-mass-type lesions were observed in 10% of cases and findings compatible with papillomatosis in 2%. Fifty five percent of the studies had no visible lesions. In the 85 patients with a pathological study of the biopsy, the sensitivity of the contrast mammography was 100%, with a diagnostic accuracy of 85%, positive and negative predictive values of 82 and 100% respectively.
Conclusions:
Contrast mammography can be of great use for the assessment of patients with an altered conventional mammography, before indicating a magnetic resonance imaging or a percutaneous biopsy.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
What is an Experiment?
Self-Evaluation: Self-Enhancement and Self-Verification
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Controls in Experiments
Randomized Experiments
Simple randomization
Simple...