Related Experiment Video
Updated: Feb 7, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Transcatheter aortic valve-in-valve implantation in failed stentless bioprostheses
Zenon Huczek1, Kajetan Grodecki1, Piotr Scisło1
11st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Objective:
To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves.
Introduction:
Little is known about ViV-TAVI in degenerated stentless valves.
Methods:
Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied.
Results:
Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963).
Conclusions:
Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Aortic Regurgitation I: Introduction