A Clinical Comparison of Linear- and Surface Area-Based Methods of Measuring Glenoid Bone Loss
Neil K Bakshi1, George A Cibulas1, Jon K Sekiya1
1MedSport, Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan, USA.
Background:
The purpose of this study was to determine whether linear-based measurement significantly overestimates glenoid bone loss in comparison with surface area-based measurement in patients with recurrent anterior shoulder instability and glenoid bone loss.
Hypothesis:
Linear-based measurement will significantly overestimate glenoid bone loss in comparison with surface area-based measurement in patients with anterior shoulder instability and glenoid bone loss.
Study Design:
Cohort study (diagnosis); Level of evidence, 3.
Methods:
Thirty patients with anterior shoulder instability underwent preoperative bilateral shoulder computed tomography (CT) scans. Three-dimensional CT (3D-CT) reconstruction with humeral head subtraction was performed to obtain an en face view of the 3D-CT glenoid. Glenoid bone loss was measured with the surface area and linear methods of measurement. Statistical analysis was performed with a paired 2-tailed t test.
Results:
Twenty-eight patients (5 female and 23 male; mean age, 25.1 years; age range, 15-58 years) were included in the study; 17 patients underwent a glenoid augmentation procedure, and 11 underwent arthroscopic Bankart repair. The mean percentage glenoid bone loss calculated with the surface area and linear methods was 12.8% ± 8.0% and 17.5% ± 9.7% ( P < .0001), respectively. For the 17 patients who underwent glenoid augmentation, mean percentage bone loss with the surface area and linear methods was 16.6% ± 7.9% and 23.0% ± 8.0% ( P < .0001), respectively.
Conclusion:
Linear measurement of glenoid bone loss significantly overestimates bone loss compared with surface area measurement in patients with anterior glenoid bony defects. These results indicate that these different methods cannot be used interchangeably and cannot be used with the same critical thresholds for glenoid bone loss.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
11:47A Novel in vivo Gene Transfer Technique and in vitro Cell Based Assays for the Study of Bone Loss in Musculoskeletal Disorders
Published on: June 8, 2014
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Linear Circuits
Linear Equations