Laser-Induced CO2 Generation from Gold Nanorod-Containing Poly(propylene carbonate)-Based Block Polymer Micelles for Ultrasound Contrast Enhancement
Related Experiment Video
Updated: Feb 7, 2026

Hydroquinone Based Synthesis of Gold Nanorods
Published on: August 10, 2016
Jaewon Lee1,2, Sung Duk Jo3, Haejun Chung4
1School of Chemical Engineering , Purdue University , West Lafayette , Indiana 47907 , United States.
Abstract:
Poly(propylene carbonate) (PPC) decomposes at high temperature to release CO2. This CO2-generation temperature of PPC can be reduced down to less than 80 °C with the aid of a photoacid generator (PAG). In the present work, we demonstrate that using an additional helper component, surface plasmonic gold nanorods (GNRs), the PPC degradation reaction can also be initiated by infrared (IR) irradiation. For this purpose, a PPC-containing nanoparticle formulation was developed in which PPC-based amphiphilic block copolymers (BCPs), poly(poly(ethylene glycol) methacrylate- b-propylene carbonate- b-poly(ethylene glycol) methacrylate) (PPEGMA-PPC-PPEGMA), were self-assembled with GNRs and PAG molecules via solvent exchange. Under IR irradiation, GNRs produce heat that can cause PPC to decompose into CO2, and PAG (after UV pretreatment) catalyzes this PPC degradation process. Two PPEGMA-PPC-PPEGMA materials were used for this study: PPEGMA7.3K-PPC5.6K-PPEGMA7.3K ("G7C6G7") and PPEGMA2.1K-PPC5.6K-PPEGMA2.1K ("G2C6G2"). Addition of CTAB-coated GNRs dispersed in water to a G2C6G2 solution in DMF produced individually G2C6G2-encapsulated GNRs, whereas the same solvent exchange procedure resulted in the formation of polymer-coated GNR clusters when G7C6G7 was used as the encapsulating material. GNR/G2C6G2 NPs exhibited a surface plasmon resonance peak at 697 nm. The clustered morphology of G7C6G7-encapsulated GNRs caused a blue shift of the absorbance maximum to 511 nm. As a consequence, GNR/G2C6G2 NPs showed a greater absorbance/heat generation rate under IR irradiation than did GNR/G7C6G7 NPs. The IR-induced CO2 generation rate was about 4.2 times higher with the GNR/G2C6G2+PAG sample than that with the GNR/G7C6G7+PAG sample. Both GNR/G7C6G7+PAG and GNR/G2C6G2+PAG systems produced ultrasound contrast enhancement effects under continuous exposure to IR light for >20 min; contrast enhancement was more spatially uniform for the GNR/G2C6G2+PAG sample. These results support the potential utility of PPC as a CO2-generating contrast agent in ultrasound imaging applications.
More Related Videos
Related Concept Videos
Polymers
Polymers
The Carbon Cycle
Carbon Skeletons
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification

