Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model
Published on: November 4, 2021
Nit-Occlud Lê VSD coil versus Duct Occluders for percutaneous perimembranous ventricular septal defect closure
Hieu Lan Nguyen1,2, Quang Tan Phan3,4, Linh Huynh Dinh2
1Intervention Center, Hanoi Medical University Hospital, Hanoi, Vietnam.
Objective:
To evaluate the efficacy and safety of Nit-Occlud Lê VSD Coil versus Duct Occluders for percutaneous closure of perimembranous ventricular septal defect (pmVSD).
Introduction:
VSD closure using conventional pmVSD occluders has been largely abandoned because of an unacceptable high rate of complete heart block (CHB). The advantages of Duct Occluders and VSD Coil are supposed to reduce the drawbacks of previous devices, especially CHB complications.
Method:
Patients underwent percutaneous pmVSD closure were divided into Coil group (using VSD Coil, n = 71) and DO group (using Duct Occluders, n = 315). Patient demographics, clinical presentations, echocardiography measurements, procedure details and follow-up data were collected.
Result:
The procedure success rate was high in both DO group (95.6%) and Coil group (97.2%, P = .53). The closure rate immediately after procedure in the DO group was higher than that in the Coil group (76.8% vs. 58.0%, P < .01). After 6 months, the closure rate was not significantly different between the 2 groups (DO group 91.3% vs. Coil group 84.1%, P = .07). The mean follow-up time was 61.4 ± 24.1 months. The major complication rate was low in both groups (DO group 1.9% vs. Coil group 1.4%, P = .78). Two patients (0.7%) in the DO group and one patient (1.4%) in the Coil group with CHB needed permanent pacemaker (P = .5). Device embolization (3 patients, 1.0%) and endocarditis (1 patient, 0.3%) occurred only in the DO group. There was no death, disability or other major complications detected in either group.
Conclusion:
Percutaneous pmVSD closure using either Nit-Occlud Lê VSD Coil or Duct Occluders is feasible, safe and efficacious in selected patients. The main problems of Duct Occluders are unsuitable defect anatomy and device embolization while VSD Coil disadvantages are residual shunt and hemolysis.
More Related Videos
07:41Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Le Chatelier's Principle: Changing Concentration
Le Chatelier's Principle: Changing Temperature
To understand this phenomenon, consider the elementary reaction:
Le Chatelier's Principle: Changing Volume (Pressure)
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Angle Closure Glaucoma: Treatment
Alveoli and Alveolar Ducts