Proton-Rocking-Chair-Type Redox Capacitors Based on Indium Tin Oxide Electrodes with Multilayer Films Containing Ru

Kai Yoshikawa1, Daisuke Motoyama1, Yusuke Hiruma1

  • 1Department of Applied Chemistry, Faculty of Science and Engineering , Chuo University , 1-13-27 Kasuga , Bunkyo-ku, Tokyo 112-8551 , Japan.

Related Concept Videos

Balancing Redox Equations02:58

Balancing Redox Equations

Electrochemistry is the science involved in the interconversion of electrical and chemical reactions. Such reactions are called reduction-oxidation, or redox reactions. These important reactions are defined by changes in oxidation states for one or more reactant elements and include a subset of reactions involving the transfer of electrons between reactant species. Electrochemistry as a field has evolved to yield sufficient insights on the fundamental principles of redox chemistry and multiple...
62.3K
Redox Reactions01:24

Redox Reactions

Oxidation-reduction or redox reactions involve the transfer of electrons from one molecule or atom to another. When an atom gains an electron, another atom must lose an electron, meaning oxidation and reduction must occur together. Since the redox occurs in pairs, the atom that gets oxidized is also called the reducing agent or reductant, and the atom that is reduced is also called the oxidizing agent or oxidant. A straightforward way to remember the definitions of oxidation and reduction is...
58.8K
Oxidation Numbers03:14

Oxidation Numbers

In redox reactions, the transfer of electrons occurs between reacting species. Electron transfer is described by a hypothetical number called the oxidation number (or oxidation state). It represents the effective charge of an atom or element, which is assigned using a set of rules.
42.9K
Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
1.4K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.1K
Standard Electrode Potentials03:02

Standard Electrode Potentials

On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
50.4K