Related Experiment Video
Updated: Feb 7, 2026

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Ahmed Glaucoma Valves versus EX-PRESS Devices in Glaucoma Secondary to Silicone Oil Emulsification
Zhuyun Qian1, Kai Xu1, Xiangmei Kong1,2,3
1Department of Ophthalmology and Visual Science, Eye, Ear, Nose, and Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China.
Objective:
To evaluate and compare the clinical effects of Ahmed glaucoma valves (AGVs) and EX-PRESS implants on glaucoma secondary to silicone oil (SO) emulsification.
Methods:
A retrospective case-series study was designed. A total of 23 eyes with late intraocular pressure (IOP) elevation secondary to SO emulsification were included in the study. Antiglaucoma surgery with implantation of AGVs or EX-PRESS devices was performed. Pre- and postoperative ocular parameters were recorded at each visit during a 1-year follow-up period. The rates of complete success (IOP < 21 mmHg without medication) and qualified success (IOP < 21 mmHg with ≤3 glaucoma medications) were analyzed.
Results:
A total of 14 eyes underwent AGV implantation, and 9 underwent EX-PRESS implantation. The mean IOP and number of medications used at the last follow-up decreased significantly compared with that before surgery (P < 0.001). The total success rate for all eyes including complete success (7/23) and qualified success (7/23) was 60.9% (14/23) at 1 year. The total success rate in the AGV group was 78.6% (11/14), whereas it was 33.3% (3/9) in the EX-PRESS group; the difference between the 2 groups was significant (P < 0.05).
Conclusion:
For glaucoma secondary to SO emulsification, glaucoma implants could be effective at lowering IOP, and AGVs might produce better outcomes than EX-PRESS devices.