Development and validation of an UHPLC-MS/MS method for simultaneous quantification of ibrutinib and its

D Beauvais1, J-F Goossens2, E Boyle3

  • 1Univ. Lille, EA 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000, Lille, France; CHU Lille, Department of Hematology, F-59000, Lille, France.

Ibrutinib is an orally administered first-in-class irreversible Bruton's tyrosine kinase (BTK) covalent inhibitor for the treatment of patients with B-cell malignancies. Several isolated clinical observations reported its efficacy in central nervous system dissemination. Herein, we described the development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) procedure for the quantification of ibrutinib and its active metabolite PCI-45227 in cerebrospinal fluid (CSF). This is the first complete validated method for quantification of ibrutinib and PCI-45227 in CSF. The compounds were eluted on a Waters BEH C18 column (50.0 × 2.1 mm; 1.7 μm) using a gradient elution with a mobile phase composed of ammonium formate buffer 5 mM pH 3.2 and acetonitrile +0.1% formic acid with a flow rate of 400 μL·min-1. Two deuterated internal standards were used to obtain the most accurate quantification. The CSF samples were prepared by a simple and rapid dilution. The method was validated by testing the selectivity, response function, intra-day and inter-day precisions, trueness, limits of detection (LOD) and lower limits of quantification (LLOQ). The validation results proved that the methods were suitable to quantify ibrutinib and PCI-45227 in real biological CSF samples from 0.50 (ibrutinib) or 1.00 (PCI-45227) to 30.00 ng·mL-1. Furthermore, the developed method was adapted to allow the quantification of both compounds in plasma and the results were compared to those reported in literature. The plasmatic samples were treated by protein precipitation and the method was validated to quantify ibrutinib and PCI-45227 in real biological plasmatic samples from 5.00 to 491 ng·mL-1. Lastly, for both matrices, accuracy profiles were plotted from the trueness and precision results using a 20% α-risk (β = 80%) and the tolerance intervals were comprised within the acceptance limits fixed at ±25% for the LLOQ and ±15% for the other concentrations. Finally, these methods were successfully applied to quantify ibrutinib and PCI-45227 in real human CSF and plasma samples.

Related Concept Videos

Cerebrospinal Fluid01:21

Cerebrospinal Fluid

Cerebrospinal fluid (CSF) is a colorless liquid that flows around the brain and the spinal cord, playing a vital role in the protection, support, and overall function of the central nervous system (CNS). CSF production, circulation, and absorption are tightly regulated processes essential for the brain and spinal cord to function properly.
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
6.0K
Reliability and Validity01:29

Reliability and Validity

Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
14.1K
In Vitro Drug Release Testing: Overview, Development and Validation01:10

In Vitro Drug Release Testing: Overview, Development and Validation

In vitro dissolution and drug release tests assess how quickly and how much of a drug is released from its dosage form into an aqueous medium under standardized laboratory conditions. These tests are essential tools in pharmaceutical development and quality assurance, offering insight into the drug's performance before clinical use.During formulation development, dissolution testing identifies incomplete or inconsistent drug release issues. It also supports decisions on selecting the optimal...
363
Development of Analytical Methods01:21

Development of Analytical Methods

An analytical methodology can be divided into four sequential steps: technique, method, procedure, and protocol. A technique is a scientific principle that rationalizes a specific phenomenon through chemical measurements. Adapting a technique for analyzing a sample of interest is termed a method. The procedure outlines the directions for performing the analysis via an analytical method. The protocol is the detailed guidelines on the procedure, which should be strictly followed to obtain the...
2.3K
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
2.1K
Data Validation01:03

Data Validation

Data validation is an essential part of a comprehensive assessment. Validation is confirming or verifying and opening the door to gathering more assessment data as it clarifies vague or unclear data. The process of checking and verifying the collected information is called data validation. The primary purpose of data validation is to ensure data is as free from error, bias, and misinterpretation as possible.
Nursing assessment guides are generally based on holistic models rather than medical...
6.8K