Related Experiment Video
Updated: Feb 7, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Incorporating the rotational setup uncertainty into the planning target volume margin expansion for the single
1Radiation Medicine, Northwell Health and Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Lake Success, New York; Department of Physics and Astronomy, Hofstra University, Hempstead, New York.
Purpose:
The single isocenter for multiple targets (SIMT) technique has become a popular treatment approach for multiple brain metastases. However, the rotational error that is introduced is usually not considered in planning target volume (PTV) expansion. We have developed a statistical model that takes into account both translational and rotational uncertainties. In this study, we incorporated the rotational error into PTV margin expansion for the clinical use of the SIMT technique.
Methods And Materials:
In the statistical model, both translational and rotational errors are assumed to follow the 3-dimensional, independent, normal distribution with a zero mean and standard deviations of σS and σR, where σR = 0.01424σD (rotational uncertainty in degree)×dI ⇔ T (distance in mm from isocenter to target). Based on this model, we derived in this study the additional PTV margin, ∆M, that is required to maintain the same coverage probability when the rotational uncertainty is present as a function of MS (initial PTV margin), σD, and dI ⇔ T. The maximum allowable dI ⇔ T, C and σD, C were also calculated as a function of user-specified ∆Mc/MS, the fraction of MS below which the extra PTV margins can be ignored.
Results:
Combined PTV margin, ME, and additional PTV margin, ∆M, were plotted for commonly encountered clinical parameters including dI ⇔ T, MS, or σD. Unlike other reported margin recipes, ∆M is not a linear function of any of these 3 parameters. In addition, the rate of increase for ∆M is quite slow for small dI ⇔ T and becomes more significant for larger dI ⇔ T. Cutoff values dI ⇔ T, C and σD, C were also plotted for various ∆Mc/MS, which can be used to determine if an additional PTV margin is needed for the SIMT technique.
Conclusions:
The presented data provide a convenient way for clinics to determine the appropriate PTV margin for the SIMT technique.
More Related Videos
Related Concept Videos
The Uncertainty Principle
Uncertainty in Measurement: Reading Instruments
Targeted Cancer Therapies
There are several types of targeted therapies against...
Targets for Drug Action: Overview
Receptors are either membrane-spanning or intracellular proteins, which upon binding a ligand, get activated and transmit the signal downstream to elicit a response. Drugs bind receptors, either mimicking the action of endogenous ligands or blocking the receptor activity to bring about a modified response. Nearly 35% of approved drugs target the G...
Target Cell Response to Hormones
Notably, the cellular response can be regulated by altering the number of receptors expressed in the cell. For example, prolonged exposure to elevated hormone levels results in a gradual decline or down-regulation in the number of receptors for that specific hormone on the cell surface. Conversely, in response to low hormone levels, cells may use up-regulation, producing an...
Uncertainty: Overview