Related Experiment Video
Updated: Feb 7, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Model-based RSA is suitable for clinical trials on the glenoid component of reverse total shoulder arthroplasty
Alexander Nilsskog Fraser1,2, Masako Tsukanaka2,3, Tore Fjalestad1
1Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.
Abstract:
This study aims to validate model-based radiostereometric analysis (RSA) on the glenoid component of reversed total shoulder arthroplasty. We compared two different modalities of model-based RSA, elementary geometrical shapes and reversed engineering. We also explored two different ways to position the patient to obtain different projections of the implant, the hip-position (transversal) and shoulder-position (sagittal). Phantom accuracy was determined by performing nine translations (x, y, z) and five rotations (x, y, z), and expressed as the mean difference between RSA measurements and micrometer values. Precision was measured using 12 double examinations of the phantom and 19 in patients, and expressed as1.96 × standard deviations of the paired differences between double examinations. The accuracy was high for both modalities, but rotation around the symmetrical axis of the implant could not be measured using reversed engineering. Clinical precision ranged from 0.13 to 0.25 mm for translations, and 0.4° to 0.7° for rotations, using reversed engineering. For elementary geometrical shapes, the precision ranged from 0.18 to 0.34 mm for translations, and 0.8° to 1.8° for rotations. The hip-position was abandoned due to poor implant visualization. Model-based RSA on the glenoid component of reversed total shoulder arthroplasty has a high precision and accuracy, comparable to RSA results on hips and knees. Patient positioning is vital for obtaining adequate results. We found that reversed engineering was the more reliable method, and recommend reversed engineering as the method of choice for further clinical RSA investigation of the glenoid component of reversed total shoulder arthroplasty. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3299-3307, 2018.
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
Modeling of Diode Reverse Characteristics
When a reverse voltage applied to a Zener diode exceeds its breakdown voltage, the diode enters the breakdown region. At this point, the...
Trial and Error and Algorithm

