Related Experiment Video
Updated: Feb 7, 2026

Asymmetric Walkway: A Novel Behavioral Assay for Studying Asymmetric Locomotion
Published on: January 15, 2016
Thrombogenicity and long-term cytokine removal capability of a novel asymmetric triacetate membrane hemofilter
Andreas Körtge1, Thomas Wild2, Benjamin Heskamp2
1Extracorporeal Immunomodulation Unit, Fraunhofer Institute for Cell Therapy and Immunology, Schillingallee 68, Room 1.06, 18057, Rostock, Germany. andreas.koertge@izi.fraunhofer.de.
Abstract:
Hemofilters applied in continuous renal replacement therapies (CRRTs) for the treatment of acute kidney injury must meet high standards in biocompatibility and permeability for middle and large molecules over extended treatment times. In general, cellulose-based membranes exhibit good biocompatibility and low fouling, and thus appear to be beneficial for CRRT. In this in vitro study, we compared a novel asymmetric cellulose triacetate (ATA) membrane with three synthetic membranes [polysulfone (PS), polyethersulfone (PES), and polyethylenimine-treated acrylonitrile/sodium methallyl sulfonate copolymer (AN69 ST)] regarding thrombogenicity and cytokine removal. For thrombogenicity assessment, we analyzed the thrombin-antithrombin complex (TAT) generation in human whole blood during 5 h recirculation and filtration. Sieving coefficients of interleukin-6 (IL-6), IL-8, IL-10, and tumor necrosis factor-alpha (TNF-α) were determined using human plasma as test fluid. ATA and AN69 ST membrane permeability were determined also during long-term experiments (48.5 h). ATA exhibited the lowest TAT generation (6.3 µg/L at 5 h), while AN69 ST induced a pronounced concentration increase (152.1 µg/L) and filter clogging during 4 out of 5 experiments. ATA (IL-8: 1.053; IL-6: 1.079; IL-10: 0.898; TNF-α: 0.493) and PES (0.973; 0.846; 0.468; 0.303) had the highest sieving coefficients, while PS (0.697; 0.100; 0.014; 0.012) and AN69 ST (N/A; 0.717; 0; 0.063) exhibited lower permeability. Long-term experiments revealed stronger fouling of the AN69 ST compared to the ATA membrane. We observed the highest permeability for the tested cytokines, the lowest thrombogenicity, and the lowest fouling with the ATA membrane. In CRRT, these factors may lead to increased therapy efficacy and lower incidence of coagulation-associated events.
Related Concept Videos
Long-term Depression
Long-term Depression
Calcium Ion Concentration Mechanism
If over...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Asymmetric Lipid Bilayer
Reduction of Alkenes: Asymmetric Catalytic Hydrogenation
The metal catalyst used can be either heterogeneous or homogeneous. When hydrogenation of an alkene generates a chiral center, a pair of enantiomeric products is expected to form. However, an enantiomeric excess of one of the products can be facilitated using an enantioselective reaction or an...
Long-term Potentiation

