The NeuroStar TMS Device: Conducting the FDA Approved Protocol for Treatment of Depression
Published on: November 12, 2010
Noninvasive Electric Current Induction for Low-Frequency Tissue Conductivity Reconstruction: Is It Feasible With a
Stefano Mandija1, Petar I Petrov2, Sebastian F W Neggers2
1Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
Abstract:
Noninvasive quantification of subject-specific low-frequency brain tissue conductivity ( ) will be valuable in different fields, for example, neuroscience. Magnetic resonance (MR)-electrical impedance tomography allows measurements of . However, the required high level of direct current injection leads to an undesirable pain sensation. Following the same principles, but avoiding pain sensation, we evaluate the feasibility of inductively inducing currents using a transcranial magnetic stimulation (TMS) device and recording the magnetic field variations arising from the induced tissue eddy currents using a standard 3 T MR scanner. Using simulations, we characterize the strength of the incident TMS magnetic field arising from the current running in the TMS coil, the strength of the induced magnetic field arising from the induced currents in tissues by TMS pulses, and the MR phase accuracy required to measure this latter magnetic field containing information about . Then, using TMS-MRI measurements, we evaluate the achievable phase accuracy for a typical TMS-MRI setup. From measurements and simulations, it is crucial to discriminate the incident from the induced magnetic field. The incident TMS magnetic field range is ±10-4 T, measurable with standard MR scanners. In contrast, the induced TMS magnetic field is much weaker (±10-8 T), leading to an MR phase contribution of ∼10-4 rad. This phase range is too small to be measured, as the phase accuracy for TMS-MRI experiments is ∼10-2 rads. Thus, although highly attractive, noninvasive measurements of the induced TMS magnetic field, and therefore estimations of , are experimentally not feasible.
Related Concept Videos
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Electrical Current
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Frequency-dependent Selection
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...