Difference between SF6 and N2 multiple breath washout kinetics is due to N2 back diffusion and error in N2 offset
Lokesh Guglani1, Ajay Kasi1, Miah Starks1
1Center for Cystic Fibrosis and Airways Disease Research, Emory University, Atlanta, Georgia.
Abstract:
Measurement of lung clearance index (LCI) by multiple breath washout (MBW) is a sensitive method for monitoring lung disease in patients with cystic fibrosis (CF). To compare nitrogen MBW (N2-MBW) and sulfur hexafluoride MBW (SF6-MBW), we connected these two gas analysis systems in series to obtain truly simultaneous measurements, with no differences other than the gas used. Nonsmoking healthy controls (HC) and subjects with CF were recruited at two institutions. The Exhalyzer-D (for N2-MBW measurement) was connected in series with the Innocor (for SF6-MBW measurement). Subjects washed in SF6 from a Douglas bag with tidal breathing and washed out SF6 and nitrogen with 100% oxygen provided as bias flow. Washout of both gases was continued past the LCI point (1/40th of equilibration concentration) in triplicate. N2-MBW resulted in higher cumulative exhaled volume, functional residual capacity (FRC), and LCI when compared with SF6-derived parameters in HC subjects (P < 0.0001 for all comparisons). All N2-MBW parameters were also significantly higher than SF6-MBW parameters in subjects with CF (P < 0.01 for all comparisons). After recalculation with a common FRC, N2-MBW LCI was higher than SF6-MBW LCI in subjects with CF (19.73 vs. 11.39; P < 0.0001) and in HC (8.12 vs. 6.78; P < 0.0001). Adjusting for N2 back diffusion and an offset error in the nitrogen measurement resulted in near complete agreement between the two methodologies. We found significant differences in LCI and FRC measurements using two different gases for MBW. This may have significant implications for the future use and interpretation of LCI data in clinical trials and routine clinical care.NEW & NOTEWORTHY This study provides important insights into the differences between the two techniques used for measuring lung clearance index (LCI): N2 and SF6 multiple breath washout. Differences between measurements made by these two methods in subjects with cystic fibrosis and healthy controls could be explained by nitrogen back diffusion and N2 offset error. This is important for use and interpretation of LCI data as an outcome measure for clinical trials and in routine clinical care.
More Related Videos
07:05Author Spotlight: Exploring the Relationship Between Lipotoxicity and HFpEF
Published on: February 23, 2024
07:06Simultaneous Evaluation of Cerebral Hemodynamics and Light Scattering Properties of the In Vivo Rat Brain Using Multispectral Diffuse Reflectance Imaging
Published on: May 7, 2017
Related Concept Videos
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
Breathing
Diffusion
Kinetic Energy
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...