Related Experiment Video
Updated: Feb 7, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at
Jorge Chacon-Caldera1, Alexander Fischer1, Matthias Malzacher1
1Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Abstract:
Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Tesla. A base array of 6-channels consisting of a flexible anterior and a rigid posterior part were built each with three loop coils. A pair of stacked resonators was added concentrically to the center loops (anterior and posterior) of the base array. The evaluated stacked resonators were butterflies, composites and dipoles which yielded a total of three 8-channel arrays. The arrays were compared using noise correlations and single-channel signal-to-noise ratio maps in a phantom. Combined signal-to-noise ratio maps and parallel imaging performances were measured and compared in vivo in 6 healthy volunteers. The results were compared to the base and a commercial array. The SNR values in the prostate yielded by all the arrays were not statistically different using fully sampled k-space. However, significant differences were found in the parallel imaging performance of the arrays. More specifically, up to 88% geometric factor reduction was found compared to the commercial array and up to 83% reduction compared to the base array using butterfly coils. Thus, signal-to-noise ratio improvements were observed with stacked resonators when using parallel imaging. The use of stacked elements, in particular butterfly coils, can improve the performance of a base array consisting solely of single loops when using parallel imaging. We expect prostate MRI at 3 Tesla to benefit from using combinations of single loops and stacked resonators.
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Resonance
Receiver Operating Characteristic Plot
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...