Development of stripping coil-ion chromatograph method and intercomparison with CEAS and LOPAP to measure atmospheric
Chaoyang Xue1, Can Ye1, Zhuobiao Ma1
1Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
Nitrous acid (HONO) is the major precursor of OH radicals in polluted areas. Accurate measurement of HONO provides vital evidence for exploring the formation of secondary pollution. Stripping coil (SC) equipped with ion chromatograph (IC) or spectrograph as one of wet chemical methods has been already used to measure HONO. The reliability of the method mainly depends on the collection efficiency and the interference from other species. In this study, a SC-IC method was set up to measure HONO. The performance of the method was assessed in the chamber using two kinds of absorption solutions i.e. ultrapure water and 25 μM Na2CO3 solution under different concentrations of SO2. Results indicated that HONO concentrations absorbed by ultrapure water and Na2CO3 solution were almost identical in the absence of SO2 in the chamber and both the collection efficiencies were >99%. However, the collection efficiency of ultrapure water decreased with the increase of SO2, indicating that the presence of SO2 resulted in the penetration of HONO. The collection efficiency kept >90% when the concentration of SO2 was no >23 ppbv. Comparing with the situation without SO2, HONO performed a remarkable increase with the presence of SO2 when using Na2CO3 absorption solution, indicating that the extra generation of HONO from the reaction between SO2 and NO2 in alkaline solution. Consequently, ultrapure water as the absorption solution could provide a high collection efficiency and avoid the interferences from SO2 when the concentration of SO2 was below 23 ppbv. High correlations (slope = 0.94-1.06, r2 > 0.90) were found during the intercomparisons between SC-IC and other three techniques, suggesting the SC-IC method developed in this study was able to measure atmospheric HONO in the field campaigns.
More Related Videos
11:48Development of a Colloidal Gold-based Immunochromatographic Test Strip for Detection of Cetacean Myoglobin
Published on: July 13, 2016
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...