Presynchronization by induction of a largest follicle using a progesterone device in GnRH-based-ovulation
L A C L Silva1, L M S Simões1, M P Bottino1
1Department of Veterinary Medicine, Universidade Federal de Lavras, Lavras, Minas Gerais, Brazil.
Abstract:
The objective was to compare the fertility of dairy cows using a presynchronization protocol by induction of a largest follicle using a progesterone intravaginal device prior to an Ovsynch protocol (P4synch) with the Double-Ovsynch in lactating dairy cows. Lactating Bos indicus x Bos taurus crossbred cows (n = 440) were randomly allocated to one of two treatments: (I) Double-Ov (n = 228), GnRH (D-17), PGF2α 7 days later (D-10) and GnRH 3 days later (D-7) followed by an Ovsynch protocol 7 days later (GnRH on D0, PGF on D7, GnRH on D9); (II) P4synch (n = 212), insertion of a sustained release progesterone intravaginal device (D-10), 10 days later (D0) an Ovsynch protocol was initiated (GnRH on D0, PGF on D7, GnRH on D9) with progesterone device withdrawal on Day 7. All cows were artificially inseminated (TAI) 16 h after the second GnRH of the Ovsynch protocol and pregnancy diagnosis was performed by transrectal ultrasonography 30 and 60 days after TAI. A subset of cows (n = 52 for Double-Ov and n = 50 for P4synch) ultrasonography was performed on days 0, 7, 9 and 24 of the experimental period. There were no differences among treatments on presynchronization rate [presence of a follicle>12 mm on D0, Double-Ov 94.2% (49/52) and P4synch 92.0% (46/50); P = 0.66], follicular diameter on the 1st GnRH (Double-Ov 17.2 ± 0.7 mm e P4synch 18.6 ± 0.9 mm; P = 0.28), ovulation rate to the 1st GnRH [Double-Ov 86.3% (44/51) and P4synch 81.2% (39/48); P = 0.50], synchronization rate [presence of a follicle>12 mm on D9; Double-Ov 84.6% (44/52) and P4synch 86.0% (43/50); P = 0.84], follicular diameter on the 2nd GnRH (Double-Ov 17.5 ± 0.6 mm and P4synch 18.0 ± 0.5 mm; P = 0.48), ovulation rate to the 2nd GnRH [Double-Ov 90.9% (40/44) and P4synch 86.0% (37/43); P = 0.48] and CL diameter on D24 (Double-Ov 27.9 ± 0.7 mm and P4synch 29.4 ± 0.9 mm; P = 0.19). Corpus luteum presence on D0 was different (P = 0.03) among treatments [Double-Ov 57.7% (30/52) and P4synch 36.0% (18/50)]. There was no difference (P = 0.85) among the pregnancy per AI on day 30 [Double-Ov 39.0% (89/228) and P4synch 40.1% (85/212)], on day 60 [Double-Ov 34.8% (79/227) and P4synch 38.7% (82/212); P = 0.41] and pregnancy loss [Double-Ov 10.2% (9/88) and P4synch 3.5% (3/85); P = 0.08]. The presynchronization by induction of a largest follicle using a sustained release progesterone device prior to Ovsynch yielded similar results compared with the Double Ovsynch protocol on follicular development patterns and on the fertility of lactating dairy cows.
More Related Videos
09:50Production and Use of Customizable Agarose Molds for Scaffold-Free Mouse Ovarian Follicle Culture
Published on: October 24, 2025
10:31Application of a Novel Hyaluronan Hydrogel for Three-Dimensional Follicle Culture and Methodology for Mouse Ovarian Follicle Cryopreservation
Published on: May 9, 2025
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Induction
A...
Self-Inductance
Consider a circuit connected to an AC source. As the current varies with time, the magnetic flux through the circuit correspondingly changes. Faraday's law tells us that an emf would...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Accessory Structures of the Skin: Hair and Hair Follicles
Hair is a keratinous filament growing out of the epidermis. It is primarily made of dead, keratinized cells. Hair strands originate at the epidermal penetration called the hair follicle. The hair shaft is the part...
Mutual Inductance
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
