Providing direction improves function: Comparison of a radial pore-orientated acellular collagen scaffold to clinical alternatives in a surgically induced rabbit diaphragmatic tissue defect model
Related Experiment Video
Updated: Feb 7, 2026

Three-Dimensional Collagen Matrix Scaffold Implantation as a Liver Regeneration Strategy
Published on: June 29, 2021
Mary Patrice Eastwood1,2, Willeke F Daamen3, Luc Joyeux1,2
1Department of Development and Regeneration, Katholieke Universiteit Leuven, Leuven, Belgium.
Abstract:
Gore-Tex® is a widely used durable patch for repair of congenital diaphragmatic defects yet may result in complications. We compared Gore-Tex with a composite of a radial pore-orientated collagen scaffold (RP-Composite) and clinically used porcine small intestinal submucosa (SIS; Surgisis®) in a rabbit model for diaphragmatic hernia. The growing rabbit mimics the rapid rib cage growth and reherniation rates seen in children. We created and immediately repaired left hemidiaphragmatic defects in 6-week-old rabbits with Gore-Tex, SIS, and an RP-Composite scaffold. An additional group of rabbits had a sham operation. At 90 days, survivors more than doubled in weight. We observed few reherniations or eventrations in Gore-Tex (17%) and RP-Composite (22%) implanted animals. However, SIS failed in all rabbits. Maximum transdiaphragmatic pressure was lower in Gore-Tex (71%) than RP-Composite implanted animals (112%) or sham (134%). Gore-Tex repairs were less compliant than RP-Composite, which behaved as sham diaphragm (p < 0.01). RP-Composite induced less foreign body giant cell reaction than Gore-Tex (p < 0.05) with more collagen deposition (p < 0.001), although there was a tendency for the scaffold to calcify. Unlike Gore-Tex, the compliance of diaphragms reconstructed with RP-Composite scaffolds were comparable with native diaphragm, whereas reherniation rates and transdiaphragmatic pressure measurements were similar.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Alternative RNA Splicing
There are five types of alternative RNA splicing that vary in the ways the pre-mRNA segments are removed or retained in the mature mRNA. The first...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Epithelial Tissues and Their Functions
Epithelial tissues provide the body's first line of protection from physical,...

