International consensus on EEG reactivity testing after cardiac arrest: Towards standardization
M M Admiraal1, A F van Rootselaar2, J Horn3
1Amsterdam UMC, University of Amsterdam, Department of Intensive Care, Amsterdam Neuroscience, Amsterdam, The Netherlands.
Resuscitation
|July 30, 2018
Summary
Electroencephalogram (EEG) reactivity testing in cardiac arrest (CA) survivors now has international consensus on stimulus protocols and interpretation. This provides best-practice guidance for predicting outcomes in comatose patients.
Area of Science:
- Neurology
- Critical Care Medicine
- Neurophysiology
Background:
- Electroencephalogram (EEG) reactivity is a proposed prognostic marker in patients after cardiac arrest (CA).
- Current guidelines for testing EEG reactivity and its interpretation are unspecific.
- Lack of standardized protocols hinders consistent clinical application.
Purpose of the Study:
- To establish international consensus on a standardized stimulus protocol for EEG reactivity testing.
- To define clear interpretation criteria for EEG reactivity in post-CA patients.
- To provide best-practice guidance for daily clinical care.
Main Methods:
- A two-round Delphi study involving 30 international experts in EEG for post-CA patients.
- Consensus defined as ≥75% agreement; 66-75% agreement resulted in recommendations.
- High response rates achieved: 80% in round one, 92% completion in round two.
Main Results:
- Consensus reached on stimulus protocol elements: clapping, calling patient's name, nail bed pressure, each repeated thrice for ≥5 seconds.
- Recommendations include pre-testing patient unstimulation and documenting sedation/analgesic use.
- Consensus definition of EEG reactivity: 'A reproducible change in the EEG in response to stimulation'.
- Exclusion criteria for reactivity: muscle/movement/eye blink artifacts, spinal movements, electrographic seizure induction.
- Agreement that the protocol is applicable to comatose patients from other etiologies.
Conclusions:
- This international consensus statement offers a starting point for EEG reactivity assessment in post-CA patients.
- The developed protocol provides best-practice guidance in the absence of extensive evidence.
- The consensus aims to improve prognostic accuracy and clinical decision-making for comatose patients.
Related Concept Videos
Testing a Claim about Standard Deviation
3.0K
A complete procedure to test a claim about population standard deviation or population variance is explained here.
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
3.0K
Internal Energy
36.8K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Internal Energy
7.1K
The internal energy of a thermodynamic system is the sum of the kinetic and potential energies of all the molecules or entities in the system. The kinetic energy of an individual molecule includes contributions due to its rotation and vibration, as well as its translational energy. The potential energy is associated only with the interactions between one molecule and the other molecules of the system. Neither the system's location nor its motion is of any consequence as far as the internal...
7.1K
Internal Receptors
74.7K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
Measurement: Standard Units
80.9K
Every measurement provides three kinds of information: the size or magnitude of the measurement (a number), a standard of comparison for the measurement (a unit), and an indication of the uncertainty of the measurement. While the number and unit are explicitly represented when a quantity is written, the uncertainty is an aspect of the errors in the measurement results.
80.9K
Cross-reactivity
33.1K
Overview
33.1K